Fast and sensitive determination of pesticide residues in vegetables using low-pressure gas chromatography with a triple quadrupole mass spectrometer

Journal

JOURNAL OF CHROMATOGRAPHY A
Volume 1128, Issue 1-2, Pages 236-243

Publisher

ELSEVIER
DOI: 10.1016/j.chroma.2006.06.044

Keywords

fast gas chromatography; low-pressure gas chromatography; triple quadrupole mass spectrometry; pesticide residues; vegetables; food analysis

Ask authors/readers for more resources

In this study, the feasibility of low-pressure gas chromatography (LP-GC) in conjunction with a triple quadrupole mass spectrometer, as a route towards fast pesticide residue analysis, was investigated. A Varian GC-MS system equipped with a mass spectrometer model 1200 was used. LP-GC-MS experiments were performed on a HP-5 10 m x 0.32 mm x 0.25 mu m analytical column connected to a 2.5 m x 0.15 mm non-coated restriction precolumn at the inlet end. For comparison purposes conventional GC-MS analysis was performed on a RTX-5 30 m x 0.25 mm x 0.5 mu m column. Under the optimized conditions the analysis time was reduced to 13.3 min with the LP-GC approach which corresponds to an almost threefold gain in speed versus the conventional GC (37 min). Despite the poorer separation power of the LP-GC column, the experiments conducted with tomato and onion extracts spiked with 78 pesticides proved that LP-GC-MS is of practical value to perform full scan screening analysis. Moreover, the rate of false negative results was higher in the case of conventional GC-MS while the LP-GC-MS enabled correct identification of pesticides at lower levels since the peaks were improved in both size and shape. Validation experiments were performed on a sample of 12 representative pesticides for comparison of performance characteristics of the LP-GC and GC approaches with mass spectrometer operated in scan, SIM and MS/MS mode. The LP-GC column set-up interfaced to the MS detector was found to be superior to the conventional GC with respect to obtained linearity, accuracy and precision parameters. Also, lower limits of detection in real extracts were achieved using the LP-GC approach. Finally, the LP-GC-MS/MS analysis of tomato samples with incurred pesticide residues demonstrated the applicability of the developed method for analysis of real samples. (c) 2006 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available