4.5 Article Proceedings Paper

High-speed three-wave polarimeter-interferometer diagnostic for Madison symmetric torus

Journal

REVIEW OF SCIENTIFIC INSTRUMENTS
Volume 77, Issue 10, Pages -

Publisher

AMER INST PHYSICS
DOI: 10.1063/1.2222332

Keywords

-

Ask authors/readers for more resources

A high-speed three-wave polarimeter-interferometer diagnostic has been developed on the Madison symmetric torus reversed field pinch to provide simultaneous measurement of electron density and poloidal magnetic field profile evolution. With increased digitizer bandwidth, polarimetry noise due to aliasing and cross-talk is minimized, and time response improved. System performance is demonstrated by measurements of equilibrium profile evolution during fast events such as the sawtooth crash and pellet injection. (c) 2006 American Institute of Physics.