4.5 Article

Poly(hydroquinone)-coated electrode for immobilizing of 5′-amine functioned capture probe DNA and electrochemical response to DNA hybridization

Journal

SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS
Volume 7, Issue 7, Pages 718-725

Publisher

NATL INST MATERIALS SCIENCE
DOI: 10.1016/j.stam.2006.06.007

Keywords

poly(hydroquinone); polymer-coated electrode; DNA; biosensor; label-free detection; AFM; QCM

Ask authors/readers for more resources

Enzymatically polymerized hydroquinone, PHQ, was applied for polymer-coated electrode whose surface was further modified with 5'-amine dodecamer DNAs (capture probe DNA, CP-DNA) by taking advantage of Michael reaction. The film-forming property of PFQ on graphite substrate surfaces was confirmed to be satisfactory by AFM imaging. Cyclic voltammetric (CV) measurements showed that the PHQ-modified graphite electrode gave well-defined redox waves showing characteristics for surface process. The pH dependence of the formal potential, E-1/2, suggested that the electrode reaction occurred by two-proton and two-electron mechanism (-59 mV per a pH decade). CVs also gave the specific amount of PHQ adsorption of 0.52 or 0.83 nmol cm(-2) (monomer unit) for the different electrode preparations. This was indicative of two- or three-monolayer adsorption of PHQ. For applications of gene detection, the immobilization reaction including the CP-DNA hybridization was studied by micro gravimetric analysis using a quartz-crystal microbalance (QCM). Summaries for the two different runs were 1.01 and 0.69 nmol cm(-2) (monomer unit) for PHQ adsorption on gold surfaces, 0.19 and 0.15 nmol cm(-2) for CP-DNA attachment on the PHQ/Au, and 0.14 and 0.11 nmol cm(-2) for hybridization with the complementary DNA on the CP-DNA/PHQ/Au, respectively. Importantly, monitoring of the series of the experiments were possible by measuring the voltammetric properties of the electrode; the distinct redox waves due to PHQ-electrode reaction are suppressed upon immobilizing of the CP-DNA, and its hybridization further suppressed the redox activity. Neither treating of the PHQ-electrode with native DNAs nor treating of CP-DNA/PHQ-electrode with non-target DNA gave no noticeable responses. A possible mechanism for the electrode response was discussed briefly based on electrochemical QCM measurements. We think these observations are important as the basis of DNA hybridization sensor that enables totally, label-free electrochemical detection of the target DNA. (c) 2006 NIMS and Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available