4.3 Article

Time-resolved pH imaging in marine sediments with a luminescent planar optode

Journal

LIMNOLOGY AND OCEANOGRAPHY-METHODS
Volume 4, Issue -, Pages 336-345

Publisher

WILEY
DOI: 10.4319/lom.2006.4.336

Keywords

-

Ask authors/readers for more resources

A laboratory-based optical pH sensor for 2-dimensional pH imaging at benthic interfaces is presented. The sensor consists of a single-layer hydrogel matrix embedding the fluorescent pH indicator 2', 7'-dihexyl-5( 6)-N-octadecyl-carboxamidofluorescein ethyl ester (DHFAE) and the phosphorescent ruthenium(II)-Tris-4,7-diphenyl-1,10- phenanthroline incorporated in nanoparticles, serving as an inert reference standard. The measuring principle is based on time domain dual-lifetime referencing (t-DLR). The fluorophore/phosphor couple is simultaneously excited by a green LED (lambda(max) 530 nm) pulsed in the microsecond range, and the sensor emission is recorded by a fast-gateable CCD camera. For each pH image, intensity images in 2 time windows ( 1 during and 1 after the excitation phase) are taken. The ratio of these 2 images is proportional to the pH of the sample and not affected by the overall signal intensity. The sensor has a dynamic range suitable for marine conditions ( pH 7.3 to 9.3) with an apparent pK(a) of 8.3. The sensor was long-term stable ( months) when kept in darkness and had a response time of < 200 s when going from pH 8.3 to 7.6. Light proved to have a negative effect on the sensor performance due to photobleaching of the pH indicator, resulting in a negative drift in the signal ratio at higher pH after prolonged light exposure. The spatial resolution (83 by 83 mu m/pixel) of the sensor was capable of resolving small-scale spatial variability in the pH at a heterogeneous sediment-water interface, and time series of calibrated pH images also expressed a marked temporal variability in the pH distribution across this interface. Hotspots with intensified microbial activity were observed, and pH minima along burrow walls of polychaetes indicated elevated diagenetic activity in these zones. Individually extracted profiles from the pH images agreed well with independently measured pH microelectrode profiles, confirming the robustness of the approach.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available