4.7 Article

Comparison of human whole blood, plasma, and serum matrices for the determination of perfluorooctanesulfonate (PFOS), perfluorooctanoate (PFOA), and other fluorochemicals

Journal

ENVIRONMENTAL RESEARCH
Volume 103, Issue 2, Pages 176-184

Publisher

ACADEMIC PRESS INC ELSEVIER SCIENCE
DOI: 10.1016/j.envres.2006.06.008

Keywords

biomonitoring; perfluorobutanesulfonate; perfluorohexanesulfonate; perfluorooctanesulfonate; perfluorooctanoate

Ask authors/readers for more resources

Interest in human exposure to perfluorinated acids, including perfluorobutanesulfonate (PFBS), perfluorohexanesulfonate (PFHS), perlluorooctanesulfonate (PFOS), and perfluorooctanoate (PFOA) has led to their measurement in whole blood, plasma and serum. Comparison of measurements in these different blood-based matrices, however, has not been rigorously investigated to allow for across-matrix comparisons. This research evaluated concentrations of PFBS, PFHS, PFOS, and PFOA in whole blood collected in heparin (lithium) and ethylenediamine tetraacetic acid (EDTA), plasma samples collected in heparin and EDTA, and serum (from whole blood allowed to clot). Blood samples were collected from 18 voluntary participants employed at 3M Company. Solid phase extraction methods were used for all analytical sample preparations, and analyses were completed using high-pressure liquid chromatography/ tandem mass spectrometry methods. Serum concentrations ranged from: limit of quantitation (LOQ, 5 ng/mL) to 25 ng/mL for PFBS; LOQ (5 ng/mL) to 75 ng/mL for PFHS; LOQ (5 ng/mL) to 880 ng/mL for PFOS; and LOQ (5 or 10 ng/mL) to 7320 ng/mL for PFOA. Values less than the LOQ were not included in the statistical analyses of the mean of the ratios of individual values for the matrices. PFBS was not quantifiable in most samples. Serum to plasma ratios for PFHS, PFOS, and PFOA were 1:1 and this ratio was independent of the level of concentrations measured. Serum or plasma to whole blood ratios, regardless of the anticoagulant used, approximated 2: 1. The difference between plasma and serum and whole blood corresponded to volume displacement by red blood cells, suggesting that the fluorochemicals are not found intracellularly or attached to the red blood cells. (c) 2006 Elsevier Inc. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available