4.5 Article

Speech understanding in background noise with the two-microphone adaptive beamformer BEAM™ in the nucleus Freedom™ cochlear implant system

Journal

EAR AND HEARING
Volume 28, Issue 1, Pages 62-72

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/01.aud.0000252470.54246.54

Keywords

-

Ask authors/readers for more resources

Objective: This paper evaluates the benefit of the two-microphone adaptive beamformer BEAM (TM) in the Nucleus Freedom (TM) cochlear implant (CI) system for speech understanding in background noise by Cl users. Design: A double-blind evaluation of the two-microphone adaptive beamformer BEAM and a hardware directional microphone was carried out with five adult Nucleus CI users. The test procedure consisted of a pre- and post-test in the lab and a 2-wk trial period at home. In the pre- and post-test, the speech reception threshold (SRT) with sentences and the percentage correct phoneme scores for CVC words were measured in quiet and background noise at different signal-to-noise ratios. Performance was assessed for two different noise configurations (with a single noise source and with three noise sources) and two different noise materials (stationary speech-weighted noise and multitalker babble). During the 2-wk trial period at home, the CI users evaluated the noise reduction performance in different listening conditions by means of the SSQ questionnaire. In addition to the perceptual evaluation, the noise reduction performance of the beamformer was measured physically as a function of the direction of the noise source. Results: Significant improvements of both the SRT in noise (average improvement of 5-16 dB) and the percentage correct phoneme scores (average improvement of 10-41%) were observed with BEAM compared to the standard hardware directional microphone. In addition, the SSQ questionnaire and subjective evaluation in controlled and real-life scenarios suggested a possible preference for the beamformer in noisy environments. Conclusions: The evaluation demonstrates that the adaptive noise reduction algorithm BEAM in the Nucleus Freedom CI-system. may significantly increase the speech perception by cochlear implantees in noisy listening conditions. This is the first mono-lateral (adaptive) noise reduction strategy actually implemented in a mainstream commercial CI.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available