4.8 Article

Rapid and onsite BOD sensing system using luminous bacterial cells-immobilized chip

Journal

BIOSENSORS & BIOELECTRONICS
Volume 22, Issue 7, Pages 1345-1350

Publisher

ELSEVIER ADVANCED TECHNOLOGY
DOI: 10.1016/j.bios.2006.06.008

Keywords

luminous bacteria; cell-based array; bio-chip; onsite detection; environmental monitoring; on-chip-biotechnology; BOD sensing

Ask authors/readers for more resources

A BOD monitoring system based on a bio-chip which immobilized luminous bacterium in micrometer-order holes were arrayed and fabricated by micro-machine techniques, was developed. The acrylic chip (3 cm x 3 cm) comprises nine micro-holes (diameter: 700 mu m or 1 mm, depth: 100 mu m) arranged in a three by three array. Cells of the marine luminous bacterium, Photobacterium phosphoreum IFO 13896, which was grown at 15 degrees C for 15 h, were immobilized with 3% or 15% sodium alginate gel. BOD standard solutions or actual sample solution (approximately 10 ld) was fallen onto the cell-arrayed chip, and then the chip was incubated at 25 degrees C for 25 min. After incubation, biolummescence from the each hole was gray-scaled and measured by a chemi-imager or newly developed onsite-type-monitoring system using a digital camera and a mobile-type personal computer. BOD values less than 16 ppm could detect by the chip, in particular, linear relationship at the concentrations between 0 and 16ppm could be observed when luminous cells were immobilized with 3% sodium alginate gel. Steady bioluminescence was observed on the chip in the presence of BOD standard solution (GGA solution) which contained mineral elements. Furthermore, simultaneous detection of BOD values in various samples could be employed in the single chip. These results showed that the monitoring system with bio-chip could achieve highthrough-put and onsite BOD detection. Our newly developed onsite-type BOD detection system which was used a digital camera and a (mobile) laptop computer was applied to measure and detect organic pollution due to biodegradable substances in wastewater treatment system. The same performance as the chemi-imager system was obtained for data of bioluminescence. The obtained BOD values showed a similar correlation with that of the conventional method for BOD determination (BOD5). These results suggested for successful achievement of high-though-put and onsite detection of BOD in practical. (c) 2006 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available