4.7 Article

Quantitative detection and rapid identification of human adenoviruses

Journal

JOURNAL OF CLINICAL MICROBIOLOGY
Volume 45, Issue 3, Pages 958-967

Publisher

AMER SOC MICROBIOLOGY
DOI: 10.1128/JCM.01603-06

Keywords

-

Categories

Ask authors/readers for more resources

We have established a method of quantitative detection and rapid identification of human adenoviruses (hAdVs). Using LightCycler PCR with a primer set, we were able to amplify 554 bp of the hexon gene from each of 51 prototype strains of hAdVs. The sensitivity of LightCycler PCR was 10 copies of hAdV DNA/reaction. When LightCycler PCR was performed using a set of primers, hAdV was positive for 74.4% (99 of 133) of conjunctivitis patients and for 27.3% (81 of 297) of respiratory infection patients. We also attempted to measure hAdV in the potentially contaminated eye drops used by patients, detecting 5.4 X 10(2) to 1.6 X 10(6) copies/ml of hAdV. We determined the 350-bp nucleotide sequence of the amplified hexon gene and compared it with the sequences of the 51 prototype strains. Phylogenetic analysis based on 350 bp of the hexon gene identified 99 positive conjunctival swabs as 24 cases of AdV type 3 (AdV-3), 14 cases of AdV-4, 1 case of AdV-8, 19 cases of AdV-19a, and 41 cases of AdV-37. The 81 sequences from pharyngeal or nasal mucus swabs were identified as 29 cases of AdV-2, 18 cases of AdV-1, 18 cases of AdV-5, 12 cases of AdV-4, 2 cases of AdV-37, I case of AdV-3, and 1 case of AdV-6. LightCycler PCR followed by phylogenetic analysis provides an effective tool for the rapid identification of hAdVs and for studying molecular epidemiology.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available