Experience with a simplified, standardized 4-hour gastric-emptying protocol

Journal

JOURNAL OF NUCLEAR MEDICINE
Volume 48, Issue 4, Pages 568-572

Publisher

SOC NUCLEAR MEDICINE INC
DOI: 10.2967/jnumed.106.036616

Keywords

gastric emptying; lag phase; stomach; gastroparesis; standardization

Ask authors/readers for more resources

Gastric-emptying studies have no accepted standard methodology or reference values. A simplified standardized protocol with a large reference database has been proposed, with imaging obtained at only 0, 1, 2, and 4 h. The rationale for its 4-h length is data suggesting that delayed emptying is detected with higher sensitivity at 4 h than at 2 h. The purpose of the current investigation was to review our 2-y experience using this protocol, to determine the added value of 4-h imaging, and to determine whether the lag phase can predict delayed emptying. Methods: After ingesting a sandwich made with Tc-99m-sulfur colloid egg substitute, 175 patients were imaged immediately, every 10 min for 1 h, and then at 2, 3, and 4 h. Percentage retention was calculated for each interval. Sensitivities, specificities, predictive values, and receiver operating characteristic (ROC) curves were computed for the 1-, 2-, and 3-h intervals on the basis of normal 4-h values. Data were analyzed to determine the added value of the 4-h study. Thresholds were sought that optimized accuracy. ROC analysis was used to determine the predictive value of the lag phase. Results: Gastric emptying was delayed in 20% of patients at 2 h and in 26% at 4 h, a 29% increase in abnormal studies (P < 0.02). Of those normal at 2 h, 13% became abnormal at 4 h. Of those with delayed emptying at 2 h, 24% normalized at 4 h. Compared with the study at 4 h, the study at 2 h had a 59% sensitivity, 94% specificity, 76% PPV, and 87% NPV. ROC analysis showed that the areas under the ROC curve (AUC) were 0.75, 0.93, and 0.97 at 1, 2, and 3 h, respectively. The threshold for optimal accuracy for 3-h data was estimated to be greater than 30% retention. The accuracy of this threshold was 91 %. The lag phase AUC for predicting delayed emptying at 4 h was 0.60. Conclusion: This first investigation of a large referral patient population using a standardized protocol found that abnormal emptying is detected with greater sensitivity at 4 h than at 2 h and that the lag phase is not predictive of delayed emptying.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available