3.9 Article Proceedings Paper

Quality assessment in high-acuity surgery - Volume and mortality are not enough

Journal

ARCHIVES OF SURGERY
Volume 142, Issue 4, Pages 371-379

Publisher

AMER MEDICAL ASSOC
DOI: 10.1001/archsurg.142.4.371

Keywords

-

Categories

Ask authors/readers for more resources

Hypothesis: A new quality assessment model for high-acuity surgery links process improvements with hospital costs and patient-centered outcomes and accurately reflects the clinical and economic impact of variance in patient acuity at the level of the practice and health care professional. Design: Retrospective case series and cost analysis. Setting: University tertiary care referral center. Patients: A total of 296 patients undergoing elective pancreatic resection in 5 years. Main Outcome Measures: Expected preoperative morbidity (evaluated using POSSUM [Physiologic and Operative Severity Score for the Enumeration of Mortality and Morbidity]) was compared with observed morbidity (according to the Clavien complication scheme) and was correlated with total hospital costs per patient. Results: As volume increased annually, patient acuity (expected morbidity) rose and complications declined. Overall, observed and expected morbidity rates were equal (54.1% vs 55.1%), for an observed-expected ratio of 0.98. Process improvement measures contributed to a steady decrease in the observed-expected morbidity ratio from 1.34 to 0.81 during the 5-year period. This decrease was strongly associated with significant cost savings as total costs per patient declined annually (from $31 541 to $18 829). This performance assessment model predicts that a 0.10 decrease in the observed-expected morbidity ratio equates to a $2549 cost savings per patient in our practice. Conclusions: Despite increasing patient acuity, better clinical and economic outcomes were achieved across time. Approaches that mitigate the impact of preoperative risk can effectively deliver quality improvement, as illustrated by a reduced observed-expected morbidity ratio. This approach is valuable in analyzing performance and process improvements and can be used to assess intrapractice and interpractice variations in high-acuity surgery.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

3.9
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available