4.6 Article

The Impact of Multilumen Infusion Devices on the Occurrence of Known Physical Drug Incompatibility: A Controlled In Vitro Study

Journal

ANESTHESIA AND ANALGESIA
Volume 116, Issue 1, Pages 101-106

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1213/ANE.0b013e31826f5e02

Keywords

-

Categories

Funding

  1. Department of Biopharmacy, Galenic
  2. Hospital Pharmacy [EA 4481, IFR114]
  3. Universite Lille Nord de France, Lille, France
  4. Doran International, Toussieu, France

Ask authors/readers for more resources

BACKGROUND: Drug incompatibility is a problem, especially when managing patients in intensive care units. We designed the present study to assess the impact of multilumen infusion access devices on the occurrence of known physical drug incompatibility through a controlled in vitro study. METHODS: Three infusion devices connected to a single-lumen catheter were studied: a standard set with 2-port manifold and 1-m extension set and 2 multilumen infusion access devices: a 3-lumen extension set and a 9-lumen extension set (Edelvaiss-Multiline (TM); Doran International, Toussieu, France). For the 9-lumen extension set, 3 infusion access combinations were studied. Furosemide, midazolam, and saline were infused simultaneously through 3 infusion devices. Three concentrations of furosemide were tested. The infusion rate of saline (carrier) was initially set at 100 mL/h and stepwise decreased by 10 mL/h until precipitate formation. Physical incompatibility was assessed by 2 tests: visual inspection and the subvisible particle count test according to the European Pharmacopeia. The lowest saline infusion rate to prevent visible precipitate and attain an acceptable particle count (i.e., to pass the 2 tests) was reported for each infusion set. RESULTS: The standard set revealed visible precipitate even at the highest saline flow rate (100 mL/h). The 3-lumen device prevented drug precipitation using the 2 lowest furosemide concentrations with a saline infusion rate that decreased with furosemide concentration. The 9-lumen infusion access device prevented drug precipitation whatever the furosemide concentration for 2 access combinations using saline infusion rates of between 20 and 60 mL/h but not for a third access combination, despite saline infusion rates equal to 100 mL/h. CONCLUSIONS: Infusion device characteristics appear to have an impact on the physical compatibility of the 2 drugs. Under specified conditions, the 9-lumen infusion access device prevents physical furosemide-midazolam incompatibility. (Anesth Analg 2013;116:101-6)

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available