4.4 Article

On the measurement of total radiated power in uncalibrated reverberation chambers

Journal

Publisher

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/TEMC.2007.897122

Keywords

emission measurement; IEC 61000-4-21; modestirred chamber; reverberation chamber (RC); total radiated power

Ask authors/readers for more resources

A novel experimental procedure to measure the total radiated power of an equipment under test (EUT) placed in a reverberation chamber (RC) is presented. In contrast to the well-established method of the IEC 61000-4-21, this new procedure does not rely on information obtained during the empty chamber calibration or the calibration with the EUT in place. Thus, the method is simpler, faster, and may have a smaller uncertainty budget.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available