4.5 Article

Absolute isotopic composition of molybdenum and the solar abundances of the p-process nuclides 92,94Mo

Journal

PHYSICAL REVIEW C
Volume 75, Issue 5, Pages -

Publisher

AMER PHYSICAL SOC
DOI: 10.1103/PhysRevC.75.055802

Keywords

-

Ask authors/readers for more resources

The isotopic composition of molybdenum has been measured with high precision using a thermal ionization mass spectrometer, the linearity of which has been verified by measuring the isotopically-certified reference material for strontium (NIST 987). The abundance sensitivity of the mass spectrometer in the vicinity of the molybdenum ion beams has been carefully examined to ensure the absence of tailing effects. Particular care was given to ensuring that potential isobaric interferences from zirconium and ruthenium did not affect the measurement of the isotopic composition of molybdenum. Gravimetric mixtures of two isotopically enriched isotopes, Mo-92 and Mo-98, were analyzed mass spectrometrically to calibrate the mass spectrometer, in order to establish the isotope fractionation of the spectrometer for the molybdenum isotopes. This enabled the absolute isotopic composition of molybdenum to be determined. An accurate determination of the isotopic composition is required in order to calculate the atomic weight of molybdenum, which is one of the least accurately known values of all the elements. The absolute isotope abundances (in atom %) of molybdenum measured in this experiment are as follows: Mo-92=14.5246 +/- 0.0015; Mo-94=9.1514 +/- 0.0074; Mo-95=15.8375 +/- 0.0098; Mo-96=16.672 +/- 0.019; Mo-97=9.5991 +/- 0.0073; Mo-98=24.391 +/- 0.018; and Mo-100=9.824 +/- 0.050, with uncertainties at the 1s level. These values enable an atomic weight A(r)(Mo) of 95.9602 +/- 0.0023 (1s) to be calculated, which is slightly higher than the current Standard Atomic Weight A(r)(Mo) =95.94 +/- 0.02 and with a much improved uncertainty interval. These absolute isotope abundances also enable the Solar System abundances of molybdenum to be calculated for astrophysical purposes. Of particular interest are the Solar System abundances of the two p-process nuclides-Mo-92 and Mo-94, which are present in far greater abundance than p-process theory suggests. The Solar System abundances for Mo-92 and Mo-94 of 0.364 +/- 0.012 and 0.230 +/- 0.008 respectively, (with respect to silicon =10(6) atoms), are the most accurate values measured to date, and should therefore be adopted in future p-process calculations, rather than the existing values of 0.378 +/- 0.021 and 0.236 +/- 0.013, respectively.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available