4.7 Article

Reproducibility of right ventricular volumes and ejection fraction using real-time three-dimensional echocardiography - Comparison with cardiac MRI

Journal

CHEST
Volume 131, Issue 6, Pages 1844-1851

Publisher

AMER COLL CHEST PHYSICIANS
DOI: 10.1378/chest.06-2143

Keywords

ejection fraction; real-time three-dimensional echocardiography; right ventricle; two-dimensional echocardiography; volumes

Ask authors/readers for more resources

Objectives: The nongeometric nature of the right ventricle (RV) makes it difficult to measure. We sought to determine whether real-time three-dimensional echocardiography (RT3DE) is superior to two-dimensional echocardiography (2DE) for the follow-up, of RV function by validation vs cardiac MRI. Methods: RV volumes and ejection fraction (EF) were studied with 2DE (including area-length [A-L], the modified two-dimensional subtraction [2DS] method, and the Simpson method of discs), RT3DE, and MRI in 50 patients with left ventricular wan motion abnormalities, the results of which suggested possible RV infarction. Test-retest variation was performed by a complete restudy using a separate sonographer within 24 h without the alteration of hemodynamics or therapy. Interobserver and intraobserver variations were noted in a subgroup of 20 patients. Results: EF estimations were similar using each technique. The mean (+/- SD) MRI end-diastolic volume (87 +/- 22 mL) was only slightly underestimated by RT3DE (mean difference, -3 +/- 10; p < 0.05), with a greater mean difference for 2DE A-L (-29 +/- 10; p < 0.05), and the Simpson method of discs (-29 23; p < 0.05), and was greatly overestimated by 2DS (mean difference, 26 +/- 23; p < 0.05). Similarly, the mean MRI end-systolic volume (46 +/- 17 mL) was only slightly underestimated by RT3DE (-4 +/- 7; p < 0.05), compared with 2DE A-L (-16 +/- 8; p < 0.05) and the Simpson method of discs (16 +/- 8; p < 0.05), and was overestimated by 2DS (14 +/- 13; p < 0.05). RT3DE findings had a higher correlation with each parameter than any 2DE technique. There was also good intraobserver and interobserver correlation between RT3DE by two sonographers. RT3DE had less test-retest variation of RV volumes and EF than any 2DE measure. Conclusions: RT3DE is more accurate than two-dimensional approaches and reduces the test-retest variation of RV volumes and EF measurements in follow-up RV assessment.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available