4.2 Article

F-18 fluorodeoxy-D-glucose positron emission tomography scan in the initial evaluation of patients with a primary melanoma thicker than 4 mm

Journal

MELANOMA RESEARCH
Volume 17, Issue 3, Pages 147-154

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/CMR.0b013e32815c10b0

Keywords

fluorodeoxyglucose; melanoma; positron emission tomography; sentinel lymph node biopsy; tumor staging

Ask authors/readers for more resources

Metabolic imaging with F-18 fluorodeoxy-D-glucose positron emission tomography is one of the most sensitive and non-invasive techniques, and has proved useful in melanoma. We designed, in 2004, at the Institute Gustave Roussy, a prospective study to determine the value of F-18 fluorodeoxy-D-glucose positron emission tomography scanning in the detection of regional and/or distant metastasis in 25 new patients referred for the treatment of a primary melanoma thicker than 4 mm (tumor node metastases stage T4). The sentinel lymph node biopsy was proposed for all the patients without a palpable regional lymph node. Abnormal positron emission tomography scan findings were correlated to available histological data and to the course of the disease. The F-18 fluorodeoxy-D-glucose positron emission tomography scan identified 0/2 intact primary melanomas, 1/4 residual primary melanomas after limited excision, 0/6 lymph node basins with micrometastasis, 4/4 lymph node basins with enlarged palpable lymph nodes and 0 distant metastasis. The sensitivity and specificity of positron emission tomography scans for microscopic lymph node disease in basins were, respectively, 0 and 92%. A false-positive F-18 fluorodeoxy-D-glucose positron emission tomography result in a cervical basin led to a useless cervical lymph node dissection. In three patients, the positron emission tomography scan was positive in distant sites but none of these foci represented a true metastasis. In conclusion, it is not useful to include a positron emission tomography scan in the initial work-up of patients with primary melanoma, even in patients with thick primary melanomas (> 4 mm). Sentinel lymph node biopsy remains the technique of choice for the most accurate initial staging. Melanoma Res 17:147-154 (C) 2007 Lippincott Williams & Wilkins.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available