Hyperpolarized 3He ventilation defects and apparent diffusion coefficients in chronic obstructive pulmonary disease -: Preliminary results at 3.0 Tesla

Journal

INVESTIGATIVE RADIOLOGY
Volume 42, Issue 6, Pages 384-391

Publisher

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/01.rli.0000262571.81771.66

Keywords

hyperpolarized (3)Helium; magnetic resonance imaging; apparent diffusion coefficient; emphysema; 3.0 Tesla

Ask authors/readers for more resources

Objective: Hyperpolarized He-3 magnetic resonance imaging (He-3 MRI) at 3.0 Tesla of healthy volunteers and chronic obstructive pulmonary disease (COPD) patients was performed for quantitative evaluation of ventilation defects and apparent diffusion coefficients (ADC) and for comparison to published results acquired at 1.5 Tesla. The reproducibility of He-3 ADC and ventilation defects was also assessed in subjects scanned 3 times, twice within 10 minutes, and again within 7 +/- 2 days of the first MRI visit. Materials and Methods: Hyperpolarized He-3 MRI was performed in 6 subjects. Two interleaved images with and without additional diffusion sensitization were acquired with the first image serving as a ventilation image from which defect score and volume were measured and the combination of the 2 images used to compute ADC maps and ADC histograms. Results: He-3 MRI at 3.0 Tesla showed increased mean ADC and ADC standard deviation for subjects with COPD compared with mild-moderate COPD (0.34 +/- 0.14 cm(2)/s), and severe COPD (0.47 +/- 0.21 cm(2)/s), and these values were similar to previously reported results acquired at 1.5 Tesla. Reproducibility of mean ADC was high (coefficient of variation 2% in severe COPD, 3% in mild-moderate COPD, 4% in healthy volunteers) across all 3 scans. Higher same-day scan reproducibility was observed for ventilation defect volume compared with I-week scan reproducibility in this small group of subjects. Conclusions: ADC values for emphysematous lungs were significantly increased compared with healthy lungs in age-matched subjects, and all values were comparable to those reported previously at 1.5 Tesla. Ventilation defect score and ventilation defect volume results were also comparable to results previously reported in COPD subjects Reproducibility of ADC for same-day scan-rescan and 7-day rescan was high and similar to previously reported results.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available