4.8 Article

Ultrasensitive Detection of Transcription Factors Using Transcription-Mediated Isothermally Exponential Amplification-Induced Chemiluminescence

Journal

ANALYTICAL CHEMISTRY
Volume 86, Issue 12, Pages 6006-6011

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/ac5017369

Keywords

-

Funding

  1. Natural Science Foundation of China [21325523]
  2. Chinese Academy of Sciences
  3. Fund for Shenzhen Engineering Laboratory of Single-molecule Detection and Instrument Development [(2012)433]

Ask authors/readers for more resources

Transcription factors (TFs) are important cellular components that modulate gene expression, and the malregulation of transcription will lead to a variety of diseases such as cancer and developmental syndromes. However, the conventional methods for transcription factor assay are generally cumbersome and costly with low sensitivity. Here, we develop a label-free strategy for ultrasensitive detection of transcription factors using a cascade signal amplification of RNA transcription, dual isothermally exponential amplification reaction (EXPAR), and G-quadruplex DNAzyme-driven chemiluminescence. Briefly, the specific binding of TF with the detecting probe prevents the cleavage of the detecting probe by exonuclease and subsequently facilitates the conversion of TF signal to abundant RNA triggers in the presence of T7 RNA polymerase. The obtained RNA triggers can initiate the strand displacement amplification to yield abundant DNAzymes and DNA triggers, and the released DNA triggers can further initiate the next rounds of EXPAR reaction. The synergistic operation of dual EXPAR reaction can produce large amounts of DNAzymes, which subsequently catalyze the oxidation of luminol by H2O2 to yield an enhanced chemiluminescence signal with the assistance of cofactor hemin. Conversely, in the absence of target TF, the naked detecting probes will be completely digested by exonucleases, leading to neither the transcription-mediated EXPAR nor the DNAzyrne-driven chemiluminescence signal. This method has a low detection limit of as low as 6.03 X 10(-15) M and a broad dynamic range from 10 fM to 1 nM and can even measure the NF-kappa B p50 of crude cell nuclear extracts. Moreover, this method can be used to measure a variety of DNA-binding proteins by simply substituting the target-specific binding sequence in the detecting probes.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available