4.3 Article

Rapid and sensitive magnetoelastic biosensors for the detection of Salmonella typhimurium in a mixed microbial population

Journal

JOURNAL OF MICROBIOLOGICAL METHODS
Volume 70, Issue 1, Pages 112-118

Publisher

ELSEVIER
DOI: 10.1016/j.mimet.2007.04.001

Keywords

biosensor; magnetoelastic; polyclonal antibodies; Salmonella typhimurium; specificity

Ask authors/readers for more resources

In this article, we report the results of an investigation into the performance of a wireless, magnetoelastic biosensor designed to selectively detect Salmonella typhimurium in a mixed microbial population. The Langmuir-Blodgett (LB) monolayer technique was employed for antibody (specific to Salmonella sp.) immobilization on rectangular shaped strip magnetoelastic sensors (2 x 0.4 x 0.015 mm). Bacterial binding to the antibody on the sensor surface changes the resonance parameters, and these changes were quantified as a shift in the sensor's resonance frequency. Response of the sensors to increasing concentrations (5 x 10(1) to 5 x 10(8) cfu/ml) of S. typhimurium in a mixture of extraneous foodborne pathogens (Escherichia coli O157 :H7 and Listeria monocytogenes) was studied. A detection limit of 5 x 103 cfu/ml and a sensitivity of 139 Hz/decade were observed for the 2 x 0.4 x 0.015 mm sensors. Binding kinetics studies have shown that the dissociation constant (Kd) and the binding valencies for water samples spiked with S. typhimurium was 435 cfu/ml and 2.33 respectively. The presence of extraneous microorganisms in the mixture did not produce an appreciable change in the biosensor's dose response behavior. (C) 2007 Elsevier B.V All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.3
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available