4.2 Article

Image-based three-dimensional treatment planning of intracavitary brachytherapy for cancer of the cervix: Dose-volume histograms of the bladder, rectum, sigmoid colon, and small bowel

Journal

BRACHYTHERAPY
Volume 6, Issue 3, Pages 187-194

Publisher

ELSEVIER SCIENCE INC
DOI: 10.1016/j.brachy.2006.11.005

Keywords

cervical cancer; brachytherapy; image-based treatment planning; dose-volume histogram; organs at risk

Ask authors/readers for more resources

PURPOSE: The purpose of this study was to evaluate dose-volume histograms (DVHs) of bladder, rectum, sigmoid colon, and small bowel using image-based three-dimensional treatment planning for intracavitary brachytherapy. METHODS AND MATERIALS: Between 2001 and 2003, 22 patients with cancer of the cervix (1 IB1, 5 IB2, 11 IIB, 5 IIIB) were treated with computerized tomography (CT)-compatible high-dose-rate intracavitary applicators and underwent postimplant pelvic CT scans with the applicator in place. The volumes of organs at risk were digitized. For radiography-based planning, International Commission on Radiation Units and Measurements (ICRU) bladder and rectum point doses were calculated. For the CT-based planning, the DVHs were computed for the bladder, rectum, sigmoid colon, and small bowel. To compare doses to organs at risk, the minimurn dose in 2.0 cm(3) volume receiving the highest dose (D-2) was determined from DVHs. These D-2 doses were compared with radiography-based ICRU point doses. RESULTS: The mean ICRU bladder point dose (401 cGy) wits markedly underestimated compared to the mean bladder D-2 dose (484 cGy). However, the mean ICRU rectal point dose (412 cGy) did not differ significantly from the mean rectal D-2 dose (373 cGy). The most frequent organ receiving the highest D-2 dose was the sigmoid colon in 9 of 22 patients (41%) followed by the rectum in 7 of 22 patients (32%) and small bowel in 6 of 22 patients (27%). CONCLUSIONS: From CT-based three-dimensional (3-D) evaluation, the ICRU bladder point dose was substantially lower than bladder D-2 dose. Special attention should also be given to the areas of proximal rectum and sigmoid colon due to more frequent high D, dose in these areas. (C) 2007 American Brachytherapy Society. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available