4.7 Article

Determination of oxygenated and native polycyclic aromatic hydrocarbons in urban dust and diesel particulate matter standard reference materials using pressurized liquid extraction and LC-GC/MS

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 407, Issue 2, Pages 427-438

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-014-8304-8

Keywords

OPAHs; PAHs; PLE; SRM1649a; SRM2975; SRM1650b

Funding

  1. Stockholm University
  2. Swedish Research Council

Ask authors/readers for more resources

The objective of this study was to develop a novel analytical chemistry method, comprised of a coupled high-performance liquid chromatography-gas chromatography/mass spectrometry system (LC-GC/MS) with low detection limits and high selectivity, for the identification and determination of oxygenated polycyclic aromatic hydrocarbons (OPAHs) and polycyclic aromatic hydrocarbons (PAHs) in urban air and diesel particulate matter. The linear range of the four OPAHs, which include 9,10-anthraquinone, 4H-cyclopenta[def]phenanthrene-4-one, benzanthrone, and 7,12-benz[a]anthraquinone, was 0.7 pg-43.3 ng with limits of detection (LODs) and limits of quantification (LOQs) on the order of 0.2-0.8 and 0.7-1.3 pg, respectively. The LODs in this study are generally lower than values reported in the literature, which can be explained by using large-volume injection. The recoveries of the OPAHs spiked onto glass fiber filters using two different pressurized liquid extraction (PLE) methods were in the ranges of 84-107 and 67-110 %, respectively. The analytical protocols were validated using the following National Institute of Standards and Technology standard reference materials: SRM 1649a (Urban Dust), SRM 1650b (Diesel Particulate Matter), and SRM 2975 (Diesel Particulate Matter, Industrial Forklift). The measured mass fractions of the OPAHs in the standard reference materials (SRMs) in this present study are higher than the values from the literature, except for benzanthrone in SRM 1649a (Urban Dust). In addition to the OPAHs, 44 PAHs could be detected and quantified from the same particulate extract used in this protocol. Using data from the literature and applying a two-sided t test at the 5 % level using Bonferroni correction, significant differences were found between the tested PLE methods for individual PAHs. However, the measured mass fractions of the PAHs were comparable, similar to, or higher than those previously reported in the literature.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available