4.7 Article

Reduction of spectral interferences using ultraclean gold nanowire arrays in the LDI-MS analysis of a model peptide

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 406, Issue 19, Pages 4571-4583

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-014-7876-7

Keywords

X-ray photoelectron spectroscopy; Surface-assisted laser desorption ionization mass spectrometry; Gold nanowire; Lithographically patterned nanowire electrodeposition

Funding

  1. Italian Project Nanomaterials & Laser Ionization Mass Spectrometry: A New Bio-analytical Approach FIRB Futuro in Ricerca - Ministero dell'Istruzione, dell'Universita e della Ricerca
  2. US National Science Foundation [CHE 1306928]
  3. Direct For Mathematical & Physical Scien [1306928] Funding Source: National Science Foundation
  4. Division Of Chemistry [1306928] Funding Source: National Science Foundation

Ask authors/readers for more resources

The surface chemistry of gold nanowires (AuNWs) has been systematically assessed in terms of contamination and cleaning processes. The nanomaterial's surface quality was correlated to its performance in the matrix-free laser desorption ionization mass spectrometry (LDI-MS) analysis of low molecular weight analytes. Arrays of AuNWs were deposited on glass slides by means of the lithographically patterned nanowire electrodeposition technique. AuNWs were then characterized in terms of surface chemical composition and morphology using X-ray photoelectron spectroscopy, scanning electron microscopy and atomic force microscopy. AuNWs were subjected to a series of well-known cleaning procedures with the aim of producing the best performing surfaces for the LDI-MS detection of leucine enkephalin, chosen as a model analyte with a molar mass below 1,000 g/mol. Prolonged cyclic voltammetry in 2 M sulfuric acid and, most of all, oxygen plasma cleaning for 5 min provided the best results in terms of simpler (interference-free) and more intense mass spectrometry spectra of the reference compound. The analyte always ionized as the sodiated adduct, and leucine enkephalin limits of detection of 0.5 and 2.5 pmol were estimated for the positive and negative analysis modes, respectively. This study points out the tight correlation existing between the chemical status of the nanostructure surface and the AuNW-assisted LDI-MS performance in terms of reproducibility of spectra, intensity of analyte ions and reduction of interferences.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available