4.7 Article

Simultaneous detection and quantification of parecoxib and valdecoxib in canine plasma by HPLC with spectrofluorimetric detection: development and validation of a new methodology

Journal

ANALYTICAL AND BIOANALYTICAL CHEMISTRY
Volume 401, Issue 5, Pages 1677-1684

Publisher

SPRINGER HEIDELBERG
DOI: 10.1007/s00216-011-5244-4

Keywords

Parecoxib; Valdecoxib; Plasma; HPLC; Fluorescence; Cox-2 inhibitor

Funding

  1. University of Pisa
  2. University of Queensland, Australia

Ask authors/readers for more resources

Parecoxib is the injectable prodrug of valdecoxib, a cicloxygenase-2 selective drug, currently used in human medicine. Recent studies have suggested both its excellent clinical effectiveness and wide safety profile. The aim of the present study was to develop and validate a new high-performance liquid chromatography (HPLC) with spectrofluorimetric detection method to quantify parecoxib and valdecoxib in canine plasma. Several parameters both in the extraction and the detection method were evaluated. The applicability of the method was determined by administering parecoxib to one dog: the protocol provided the expected pharmacokinetic results. The final mobile phase was acetonitrile: AcONH4 (10 mM; pH 5.0) 55:45, v/v, with a flow rate of 0.4 mL min(-1), and excitation and emission wavelengths of 265 and 375 nm, respectively. The analytical column was a reverse-phase C18 ODS2 3-mu m particle size. Protein precipitation in acidic medium followed by two successive liquid-liquid steps was carried out. The best extraction solvent was cyclohexane:Et2O (3:2, v/v) that gave recoveries ranging from 81.1% to 89.1% and from 94.8% to 103.6% for parecoxib and valdecoxib, respectively. The limits of quantification were 25 and 10 ng mL(-1) for parecoxib and valdecoxib, respectively. The chromatographic runs were specific with no interfering peaks at the retention times of the analytes, as confirmed by HPLC-mass spectrometry experiments. The other validation parameters were in agreement with the European Medicines Evaluation Agency and International Conference on Harmonisation guidelines. In conclusion, this method (extraction, separation and applied techniques) is simple and effective. This is the first time that use of a HPLC with spectrofluorimetric detection technique to simultaneously detect parecoxib and valdecoxib in plasma has been reported. This technique may have applications for pharmacokinetic studies.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available