4.7 Review

Matrix enhancement effect: A blessing or a curse for gas chromatography? - A review

Journal

ANALYTICA CHIMICA ACTA
Volume 801, Issue -, Pages 14-21

Publisher

ELSEVIER
DOI: 10.1016/j.aca.2013.09.005

Keywords

Gas chromatography; Matrix effect; Sensitivity; Analyte protectants; Signal enhancement; Thermal protection

Funding

  1. MSIP (Ministry of Science, Ict & future Planning)
  2. National Research Foundation of Korea [22A20130000101] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

Ask authors/readers for more resources

The matrix enhancement effect in gas chromatography (GC) has been a problem for the last decade and results in unexpected high recovery. Most efforts, including the use of different types of injectors/matrix simplification procedures, and further clean-up associated with removing this effect has focused on equalizing the response of the standard in the solvent and matrix. However, after eliminating the matrix enhancement effect, the sensitivity of GC remained unchanged. But, GC sensitivity can be increased by utilizing this matrix effect originating from a matrix-matched standard. Very few studies have highlighted utilizing the matrix effect but have rather advocated eliminating it. Analyte protectants (3-ethoxy-1,2-propanediol, gulonolactone and sorbitol) have been introduced as an alternative for GC-mass spectroscopy (GC-MS) (not examined for other GC detectors), as they equalize the response without removing the matrix effect, and, hence, increase sensitivity. Versatile applications of analyte protectants are not observed in practice. The European guidelines recommend the use of matrix-matched standard calibration for residue measurements. As a result, numerous applications are available for matrix-matched standards that compensate for the matrix effect. Moreover, the matrices (among them pepper leaf matrix) act as a protectant for thermolabile analytes in some cases. A lower detection limit should be achieved to comply with the maximum residue limits. Therefore, the matrix enhancement effect, which is considered a problem, can play an important role in lowering the detection limit by increasing the transfer of analyte from the injection port to the detector. (C) 2013 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available