4.7 Article

Cadmium (II) imprinted 3-mercaptopropyltrimethoxysilane coated stir bar for selective extraction of trace cadmium from environmental water samples followed by inductively coupled plasma mass spectrometry detection

Journal

ANALYTICA CHIMICA ACTA
Volume 723, Issue -, Pages 54-60

Publisher

ELSEVIER
DOI: 10.1016/j.aca.2012.02.027

Keywords

Stir bar sorptive extraction; Cadmium (II) imprinted 3-mercaptopropyltrimethoxysilane coating; Double-imprinting; Sol-gel technique; Environmental water sample; Inductively coupled plasma mass; spectrometry

Funding

  1. National Nature Science Foundation of China [20775057]
  2. NSFC [20621502, 20921062]
  3. MOE of China [NCET-04-0658]

Ask authors/readers for more resources

Cd(II) imprinted 3-mercaptopropyltrimethoxysilane (MPTS)-silica coated stir bar was prepared by sol-gel technique combining with a double-imprinting concept for the first time and was employed for stir bar sorptive extraction (SBSE) of trace Cd(II) from water samples followed by inductively coupled plasma mass spectrometry (ICP-MS) detection. A tetramethoxysilane (TMOS) coating was first in situ created on the glass bar surface. Afterward, a sol solution containing MPTS as the functional precursor, ethanol as the solvent and both Cd(II) and surfactant micelles (cetyltrimethylammonium bromide, CTAB) as the template was again coated on the TMOS bar. The structures of the stir bar coating were characterized by FT-IR spectroscopy. Round-bottom vial was used for the extraction of Cd(II) by SBSE to avoid abrasion of stir bar coatings. The factors affecting the extraction of Cd(II) by SBSE such as pH, stirring rate and time, sample/elution volume and interfering ions have been investigated in detail, and the optimized experimental parameters were obtained. Under the optimized conditions, the adsorption capacities of non-imprinted and imprinted coating stir bars were found to be 0.5 mu g and 0.8 mu g bar(-1). The detection limit (3 sigma) based on three times standard deviations of the method blanks by 7 replicates was 4.40 ng L-1 and the relative standard deviation (RSD) was 3.38% (c = 1 mu g L-1, n = 7). The proposed method was successfully applied for the analysis of trace Cd(II) in rain water. East Lake and Yangtze River water. To validate the proposed method, certified reference material of GSBZ 50009-88 environmental water was analyzed and the determined value is in a good agreement with the certified value. The developed method is rapid, selective, sensitive and applicable for the analysis of trace Cd(II) in environmental water samples. (C) 2012 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available