4.7 Article

Mid-infrared spectrometry of milk for dairy metabolomics: A comparison of two sampling techniques and effect of homogenization

Journal

ANALYTICA CHIMICA ACTA
Volume 705, Issue 1-2, Pages 88-97

Publisher

ELSEVIER
DOI: 10.1016/j.aca.2011.04.018

Keywords

Fourier transform infrared spectroscopy; Attenuated total reflection; High throughput transmission; Ultrasonic homogenization; Milk analysis; Health monitoring

Ask authors/readers for more resources

Milk production is a dominant factor in the metabolism of dairy cows involving a very intensive interaction with the blood circulation. As a result, the extracted milk contains valuable information on the metabolic status of the cow. On-line measurement of milk components during milking two or more times a day would promote early detection of systemic and local alterations, thus providing a great input for strategic and management decisions. The objective of this study was to investigate the potential of mid-infrared (mid-IR) spectroscopy to measure the milk composition using two different measurement modes: micro attenuated total reflection (mu ATR) and high throughput transmission (HTT). Partial least squares (PLS) regression was used for prediction of fat, crude protein, lactose and urea after preprocessing IR data and selecting the most informative wavenumber variables. The prediction accuracies were determined separately for raw and homogenized copies of a wide range of milk samples in order to estimate the possibility for on-line analysis of the milk. In case of fat content both measurement modes resulted in an excellent prediction for homogenized samples (R-2 > 0.92) but in poor results for raw samples (R-2 < 0.70). Homogenization was however not mandatory to achieve good predictions for crude protein and lactose with both mu ATR and HTT, and urea with mu AIR spectroscopy. Excellent results were obtained for prediction of crude protein, lactose and urea content (R-2 > 0.99, 0.98 and 0.86 respectively) in raw and homogenized milk using mu ATR IR spectroscopy. These results were significantly better than those obtained by HIT IR spectroscopy. However, the prediction performance of HIT was still good for crude protein and lactose content (R-2 > 0.86 and 0.78 respectively) in raw and homogenized samples. However, the detection of urea in milk with HTT spectroscopy was significantly better (R-2 = 0.69 versus 0.16) after homogenization of the milk samples. Based on these observations it can be concluded that mu ATR approach is most suitable for rapid at line or even on-line milk composition measurement, although homogenization is crucial to achieve good prediction of the fat content. (C) 2011 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available