4.7 Article

Highly sensitive determination of hydroxylamine using fused gold nanoparticles immobilized on sol-gel film modified gold electrode

Journal

ANALYTICA CHIMICA ACTA
Volume 663, Issue 2, Pages 158-164

Publisher

ELSEVIER
DOI: 10.1016/j.aca.2010.01.045

Keywords

Fused AuNPs; (3-mercaptopropyl)-trimethoxysilane sol-gel film; 2-Mercapto-4-methyl-5-thiazoleacetic acid; Hydroxylamine; Amperometry

Funding

  1. University [F-31-131/2005]
  2. Council of Scientific and Industrial Research (CSIR), New Delhi [09/715 (0009)/2008-EMR-l]
  3. Department of Science and Technology, New Delhi [SR/NM/NS-28/2008]

Ask authors/readers for more resources

We are reporting the highly sensitive determination of hydroxylamine (HA) using 2-mercapto-4-methyl-5-thiazoleacetic acid (TAA) capped fused spherical gold nanoparticles (AuNPs) modified Au electrode. The fused TAA-AuNPs were immobilized on (3-mercaptopropyl)-trimethoxysilane (MPTS) sol-gel film, which was pre-assembled on Au electrode. The immobilization of fused TAA-AuNPs on MPTS sol-gel film was confirmed by UV-vis absorption spectroscopy and atomic force microscopy (AFM). The AFM image showed that the AuNPs retained the fused spherical morphology after immobilized on sol-gel film. The fused TAA-AuNPs on MPTS modified Au electrode were used for the determination of HA in phosphate buffer (PB) solution (pH = 7.2). When compared to bare Au electrode, the fused AuNPs modified electrode not only shifted the oxidation potential of HA towards less positive potential but also enhanced its oxidation peak current. Further, the oxidation of HA was highly stable at fused AuNPs modified electrode. Using amperometric method, determination of 17.5 nM HA was achieved for the first time. Further, the current response of HA increases linearly while increasing its concentration from 17.5 nM to 22 mM and a detection limit was found to be 0.39 nM (S/N= 3). The present modified electrode was also successfully used for the determination of 17.5 nM HA in the presence of 200-fold excess of common interferents such as urea, NO2-, NH4+, oxalate, Mn-2(+), Na+, Mg2+, Ca2+, Ba2+ and Cu2+. The practical application of the present modified electrode was demonstrated by measuring the concentration of HA in ground water samples. (C) 2010 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available