4.7 Article

Evaluation of ultrasound-assisted extraction as sample pre-treatment for quantitative determination of rare earth elements in marine biological tissues by inductively coupled plasma-mass spectrometry

Journal

ANALYTICA CHIMICA ACTA
Volume 679, Issue 1-2, Pages 49-55

Publisher

ELSEVIER
DOI: 10.1016/j.aca.2010.09.004

Keywords

Rare earth elements; Ultrasound assisted extraction; Inductively-coupled plasma mass spectrometry; Marine biological tissues

Funding

  1. Spanish Ministry of Science and Innovation [CTQ2009-06956/BQU]
  2. Vigo University [09VIA08]
  3. Universidade de Vigo

Ask authors/readers for more resources

In this work the determination of rare earth elements (REEs) i e V La Ce Pr Nd Sm Eu Gd Tb Dy Ho Er Tm Yb and Lu in marine biological tissues by inductively coupled-mass spectrometry (ICP-MS) after a sample preparation method based on ultrasound-assisted extraction (UAE) is described The suitability of the extracts for ICP-MS measurements was evaluated For that studies were focused on the following issues (i) use of clean up of extracts with a C18 cartridge for non-polar solid phase extraction (ii) use of different internal standards (iii) signal drift caused by changes in the nebulization efficiency and salt deposition on the cones during the analysis The signal drift produced by direct introduction of biological extracts in the instrument was evaluated using a calibration verification standard for bracketing (standard-sample bracketing SSB) and cumulative sum (CUSUM) control charts Parameters influencing extraction such as extractant composition mass-to-volume ratio particle size sonication time and sonication amplitude were optimized Diluted single acids (HNO3 and HCl) and mixtures (HNO3 + HCl) were evaluated for improving the extraction efficiency Quantitative recoveries for REEs were achieved using 5 mL of 3% (v/v) HNO3 + 2% (v/v) HCl particle size <200 mu m 3 min of sonication time and 50% of sonication amplitude Precision expressed as relative standard deviation from three independent extractions ranged from 0 1 to 8% In general LODs were improved by a factor of 5 in comparison with those obtained after microwave-assisted digestion (MAD) The accuracy of the method was evaluated using the CRM BCR-668 (mussel tissue) Different seafood samples of common consumption were analyzed by ICP-MS after UAE and MAD (C) 2010 Elsevier B V All rights reserved

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available