4.7 Article

A sensitive fluorescence reagent for the determination of aldehydes from alcoholic beverage using high-performance liquid chromatography with fluorescence detection and mass spectrometric identification

Journal

ANALYTICA CHIMICA ACTA
Volume 636, Issue 1, Pages 95-104

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2009.01.036

Keywords

Column liquid chromatography; Aldehydes; 2-[2-(7H-dibenzo[a,g] carbazol-7-yl)-ethoxyl ethyl carbonylhydrazine (DBCEEC); Mass spectrometry

Funding

  1. National Science Foundation of China [20075016]
  2. Chinese Academy of Sciences [328]

Ask authors/readers for more resources

A pre-column derivatization method for the sensitive determination of aldehydes using the tagging reagent 2-[2-(7H-dibenzo[a,g] carbazol-7-yl)-ethoxyl ethyl carbonylhydrazine (DBCEEC) followed by high-performance liquid chromatography with fluorescence detection and APCI-MS identification has been developed. The chromophore of fluoren-9-methoxy-carbonylhydrazine (Fmoc-hydrazine) reagent was replaced by 2-[2-(7H-dibenzo[a,g] carbazol-7-yl)-ethoxyl ethyl functional group, which resulted in a sensitive fluorescence tagging reagent DBCEEC. DBCEEC Could easily and quickly labeled aldehydes. The maximum excitation (300 nm) and emission (400 nm) wavelengths did not essentially change for all the aldehyde derivatives. Derivatives were sufficiently stable to be efficiently analyzed by high-performance liquid chromatography. The derivatives showed an intense protonated molecular ion corresponding m/z [M + (CH(2))(n)](+) in positive-ion mode (M: molecular weight of DBCEEC, n: corresponding aldehyde carbon atom numbers). The collision-induced dissociation of protonated molecular ion formed fragment ions at m/z 294.6, m/z 338.6 and m/z 356.5. Studies on derivatization demonstrated excellent derivative yields in the presence of trichloroacetic acid (TCA) catalyst. Maximal yields close to 100% were observed with a 10 to 15-fold molar reagent excess. Separation of the derivatized aldehydes had been optimized on ZORBAX Eclipse XDB-C(8) column with aqueous acetonitrile as mobile phase in conjunction with a binary gradient elution. Excellent linear responses were observed at the concentration range of 0.01-10 nmol mL(-1) with coefficients of >0.9991. Detection limits obtained by the analysis of a derivatized standard containing 0.01 nmol mL(-1) of each aldehyde, were from 0.2 to 1.78 nmol L(-1) (at a signal-to-noise ratio of 3). (C) 2009 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available