4.7 Article

A simple fluorescent probe for the determination of dissolved oxygen based on the catalytic activation of oxygen by iron(II) chelates

Journal

ANALYTICA CHIMICA ACTA
Volume 640, Issue 1-2, Pages 63-67

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2009.03.024

Keywords

Dissolved oxygen; Catalytic activation; Iron(II) chelates; Fluorescent probe; Coumarin

Funding

  1. National Natural Science Foundation of China [20877031, 20677019]
  2. State Key Laboratory of Pollution Control and Resource Reuse Foundation [PCRRF08007]

Ask authors/readers for more resources

This work aims at establishing a simple fluorescent probe for the determination of dissolved oxygen. It is found that iron(II) ions activate oxygen to produce reactive species being capable of oxidizing non-fluorescent coumarin to fluorescent 7-hydroxycoumarin. However, this process is not effective because the yield of the reactive species is very low in the presence of simple iron(II) salts alone. The addition of organic ligands such as oxalate results in the formation of complexes between iron(II) ions, which leads to considerable increase in the yield of reactive species (such as hydroxyl radicals) and then increase in the fluorescence intensity of 7-hydroxycoumarin to a significant level. It has been observed that in the mixture solution of iron(II) ions, ligand, coumarin, and dissolved oxygen, there is an excellent linear response between the fluorescence and dissolved oxygen. Therefore, a new spectrofluorimetric method has been proposed for the determination of dissolved oxygen by using catalytic activation of O-2 by iron(II) chelates. Under optimized conditions, a linear correlation (r = 0.995) has been observed between the fluorescence intensity of 7-hydroxycoumarin at 456 nm and the concentration of dissolved oxygen over the range of 0.96-9.22 mg L-1. The limit of detection for dissolved oxygen at a signal-to-noise ratio of 3 has been estimated to be 0.35 mg L-1. The proposed method has been applied to determine the concentration of dissolved oxygen in practical water samples with results as satisfactory as that obtained by the standard iodometric method. (c) 2009 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available