4.7 Article

Evaluation of alternate lines of Fe for sequential multi-element determination of Cu, Fe, Mn and Zn in soil extracts by high-resolution continuum source flame atomic absorption spectrometry

Journal

ANALYTICA CHIMICA ACTA
Volume 627, Issue 2, Pages 198-202

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.aca.2008.08.016

Keywords

Micronutrients; Soil; High-resolution continuum source flame atomic spectrometry; Side pixel registration

Funding

  1. Fundacao de Amparo a Pesquisa do Estado de Sao Paulo
  2. Coordenacao de Pessoal de Ensino Superior
  3. Conselho Nacional de Desenvolvimento Cientifico e Tecnologico

Ask authors/readers for more resources

The usefulness of the secondary line at 252.744 nm and the approach of side pixel registration were evaluated for the development of a method for sequential multi-element determination of Cu, Fe, Mn and Zn in soil extracts by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The influence of side pixel registration on the sensitivity and linearity was investigated by measuring at wings (248.325, 248.323, 248.321, 248.329, and 248.332 nm) of the main line for Fe at 248.327 nm. For the secondary line at 252.744 nm or side pixel registration at 248.325 nm, main lines for Cu (324.754 nm), Mn (279.482 nm) and Zn (213.875 nm), sample flow-rate of 5.0 mL min(-1) and calibration by matrix matching, analytical curves in the 0.2-1.0 mg L-1 Cu, 1.0-20.0 mg L-1 Fe, 0.2-2.0 mg L-1 Mn, 0.1-1.0 mg L-1 Zn ranges were obtained with linear correlations better than 0.998. The proposed method was applied to seven soil samples and two soil reference materials (IAC 277; IAC 280). Results were in agreement at a 95% confidence level (paired t-test) with reference values. Recoveries of analytes added to soil extracts containing 0.15 and 0.30 mg L-1 Cu, 7.0 and 14 mg L-1 Fe, 0.60 and 1.20 mg L-1 Mn, 0.07 and 0.15 mg L-1 Zn, varied within the 94-99, 92-98, 93-101, and 93-103% intervals, respectively. The relative standard deviations (n = 12) were 2.7% (Cu), 1.4% (Fe - 252.744 nm), 5.7% (Fe - 248.325 nm), 3.2% (Mn) and 2.8% (Zn) for an extract containing 0.35 mg L-1 Cu, 14 mg L-1 Fe, 1.1 mg L-1 Mn and 0.12 mg L-1 Zn. Detection limits were 5.4 mu g L-1 Cu, 55 mu g L-1 Fe (252.744 nm), 147 mu g L-1 Fe (248.325 nm), 3.0 mu g L-1 Mn and 4.2 mu g L-1 Zn. (C) 2008 Published by Elsevier B.V.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available