4.6 Article

A novel electrochemical immunoassay for carcinoembryonic antigen based on glucose oxidase-encapsulated nanogold hollow spheres with a pH meter readout

Journal

ANALYST
Volume 143, Issue 21, Pages 5271-5277

Publisher

ROYAL SOC CHEMISTRY
DOI: 10.1039/c8an01436a

Keywords

-

Funding

  1. Young Talent Support Program of Xiamen Maternal and Child Health Care Hospital [[2018]26]

Ask authors/readers for more resources

A portable electrochemical immunosensing protocol was designed for the sensitive detection of a disease-related tumor biomarker (carcinoembryonic antigen, CEA, used in this case) on a pH meter using glucose oxidase (GOx)-encapsulated gold hollow microspheres (AuHMs) for signal amplification. The assay was carried out on a monoclonal anti-CEA capture antibody-coated microplate with a sandwich-type reaction mode. The GOx-entrapped AuHM was first synthesized using the reverse micelle method and then used as the signal-generation tag for the labeling of polyclonal anti-CEA detection antibody. Accompanying the formation of the sandwiched immunocomplexes, the loaded GOx molecules in the microsphere could catalyze glucose into gluconic acid and hydrogen peroxide. The as-produced gluconic acid changed the microenvironment of the detection solution, thus resulting in the shift of the pH value, which could be quantitatively determined on a portable pH meter. The use of gold hollow microspheres was expected to enhance the loaded amount of GOx for signal amplification. Two labeling protocols including GOx-labeled secondary antibody and GOx-AuHM-labeled secondary antibody were investigated for CEA detection, and improved analytical features were acquired with GOx-AuHM labeling. With the GOx-AuHM labeling strategy, the pH meter-based immunosensing device exhibited a good analytical performance for CEA detection within the dynamic linear range of 0.1-100 ng mL(-1) at a detection limit of 0.062 ng mL(-1). The strong attachment of anti-CEA antibodies to GOx-AuHM brought a good repeatability and intermediate precision down to 10%. Importantly, no significant differences at the 0.05 significance level were encountered in the analysis of 12 human serum specimens between the developed immunoassay and the commercialized electrochemiluminescent method for CEA determination.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available