4.0 Article Proceedings Paper

Cardiac extracorporeal life support: state of the art in 2007

Journal

CARDIOLOGY IN THE YOUNG
Volume 17, Issue -, Pages 104-115

Publisher

CAMBRIDGE UNIV PRESS
DOI: 10.1017/S1047951107001217

Keywords

extracorporeal membrane oxygenation; ventricular assist device; low cardiac output syndrome; cardiogenic shock; cardiopulmonary resuscitation

Ask authors/readers for more resources

Mechanical circulatory support is an invaluable tool in the care of children with severe refractory cardiac and or pulmonary failure. Two forms of mechanical circulatory support are currently available to neonates, infants, and smaller children, namely extracorporeal membrane oxygenation and use of a ventricular assist device, with each technique having unique advantages and disadvantages. The intra-aortic balloon pump is a third form of mechanical support that has been successfully used in larger children, adolescents, and adults, but has limited applicability in smaller children. In this review, we discuss the current experiences with extracorporeal. membrane oxygenation and ventricular assist devices in children with cardiac disease. A variety of forms of mechanical circulatory support are available for children with cardiopulmonary dysfunction refractory to conventional management. These devices require extensive resources, both human and economic. Extracorporeal membrane oxygenation can be effectively used in a variety of settings to provide support to critically-ill patients with cardiac disease. Careful selection of patients and timing of intervention remains challenging. Special consideration should be given to children with cardiac disease with regard to anatomy, physiology, cannulation, and circuit management. Even though exciting progress is being made in the development of ventricular assist devices for long-term mechanical support in children, extracorporeal membrane oxygenation remains the mainstay of mechanical circulatory support in children with complex anatomy, particularly those needing rapid resuscitation and those with a functionally univentricular circulation. As the familiarity and experience with extracorporeal. membrane oxygenation has grown, new indications have evolved, including emergent resuscitation. This utilization has been termed extracorporeal cardiopulmonary resuscitation. The literature supporting emergent cardiopulmonary support is mounting. Reasonable survival rates have been achieved after initiation of support during active compressions of the chest following in-hospital cardiac arrest. Due to the limitations of conventional circuits for extracorporeal membrane oxygenation, some centres have developed novel systems for rapid cardiopulmonary support. Many centres previously considered a functionally univentricular circulation to be a contraindication to extracorporeal membrane oxygenation, but improved results have been achieved recently with this complex subset of patients. The registry of the Extracorporeal Life Support Organization recently reported the outcome of extracorporeal life support used in neonates for cardiac indications from 1996 to 2000. Of the 740 neonates whowere placed on extracorporeal life support for cardiac indications, 118 had hypoplastic left heart syndrome. There was no significant difference in survival between these patients and those with other defects. It is now common to use extracorporeal membrane oxygenation to support patients with a functionally univentricular circulation, and reasonable survival rates are to be expected. Although extracorporeal membrane oxygenation has become a standard of care for many paediatric centres, its use is limited to those patients who require only short-term cardiopulmonary support. Mechanical ventricular assist devices have become standard therapy for adults with cardiac failure refractory to maximal medical management. Several devices are readily available in the United States of America for adults, but there are fewer options available to children. Over the last few years, substantial progress has been made in paediatric mechanical support. Ventricular assist devices are being used with increasing frequency in children with cardiac failure refractory to medical therapy for primary treatment as a long-term bridge to recovery or transplantation. The paracorporeal, pneumatic, pulsatile Berlin Heart ventricular assist device is being used with increasing frequency in Europe and North America to provide univentricular and biventricular support. With this device, a patient can be maintained on mechanical circulatory support while extubated, being mobilized, and feeding by mouth. Mechanical circulatory support should be anticipated, and every attempt must be made to initiate support urgently rather than emergently, before the presence of dysfunction of end organs or circulatory collapse. In an emergency, these patients can be resuscitated with extracorporeal membrane oxygenation and subsequently transitioned to a long-term ventricular assist device after a period of stability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.0
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available