4.7 Article Proceedings Paper

Robust flow-batch coulometric/biamperometric titration system: Determination of bromine index and bromine number of petrochemicals

Journal

ANALYTICA CHIMICA ACTA
Volume 600, Issue 1-2, Pages 84-89

Publisher

ELSEVIER
DOI: 10.1016/j.aca.2006.12.039

Keywords

flow analysis; flow-batch titration; coulometry; biamperometry; bromine index; bromine number; petrochemicals

Ask authors/readers for more resources

A flow-batch system was constructed and evaluated to perform coulometric titrations with biamperometric end point detection. The flow section of the system is employed for sampling by injecting a sample volume (50-300 mu L) in a flow injection-like system. About 1.5 mL of a suitable carrier solution is delivered by a peristaltic pump in order to quantitatively transfer the sample to the system titration cell (2.0mL total inner volume). The carrier contains the coulometric precursor for the titrant species. The cell contains two pairs of platinum electrodes used for coulometric generation of reagent and biamperometric detection and is actively stirred. The titrant species is generated and the titration is performed by the usual batch procedure with the excess of titrant being detected by biamperometry following the analysis of the titration curve. System operation is computer controlled and all operations are automated, including titration curve analysis and cell cleaning after the titration is ended. The system is characterized by its robustness because its operation does not depend on flow rates, and the work using coulometric methods which generate gases at the counter-electrode is not troublesome. The flow-batch system has been evaluated for determination of bromine index and bromine number (relative to the total reactive olefin content) in petrochemicals according to an ASTM procedure. Typical precision (R.S.D.) is between 0.5 and 6% for different petrochemicals whose bromine number/index vary from 1000 to 10 mg of bromine per 100 g of sample, respectively. Recoveries for standard additions are between 92 and 123% for 10 mg of Br-2 per 100 g increments and 98 to 101% for 100 mg per 100 g increments. Accuracy of the proposed system was evaluated against results obtained by the standard ASTM with no significant difference detected at 95% confidence level. (C) 2007 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.7
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available