4.5 Article

The effect of haemodynamic and peripheral vascular variability on cardiac output monitoring: thermodilution and non-invasive pulse contour cardiac output during cardiothoracic surgery

Journal

ANAESTHESIA
Volume 73, Issue 12, Pages 1489-1499

Publisher

WILEY
DOI: 10.1111/anae.14380

Keywords

continuous cardiac output; finger arterial pressure; validation

Categories

Funding

  1. Netherlands Heart Foundation, The Hague, the Netherlands [2006B027]
  2. BMEYE, Amsterdam, the Netherlands
  3. Dutch Diabetes Foundation, Amersfoort, the Netherlands [2004.00.00]
  4. NWO, The Hague, the Netherlands [VICI 2002406]

Ask authors/readers for more resources

While haemodynamic variability interferes with the assumption of constant flow underlying thermodilution cardiac output calculation, variability in (peripheral) arterial vascular physiology may affect pulse contour cardiac output methods. We compared non-invasive finger arterial pressure-derived continuous cardiac output measurements (Nexfin((R))) with cardiac output measured using thermodilution during cardiothoracic surgery and determined the impact of cardiovascular variability on either method. We compared cardiac output derived from non-invasive finger arterial pressure with cardiac output measured by thermodilution at four grades (A-D) of cardiovascular variability. We defined Grade A data as heart rate and mean arterial pressure variability < 5% and the absence of arrhythmias (implying stable flow) and Physiocal((R)) interval (as measure of variability in finger arterial physiology) > 30 beats. Grade B included all levels of heart rate/mean arterial pressure variability and arrhythmias (Physiocal < 30 excluded). Grade C included all Physiocal intervals (heart rate/mean arterial pressure variability > 5% and arrhythmias excluded). Grade D included all data. Comparison results were quantified as percentage errors. We analysed measurements in 27 patients undergoing coronary artery bypass surgery. Before extracorporeal circulation, the percentage error was 23% (n = 14 patients) in grade A, 28% (n = 20) in grade B, 32% (n = 22) in grade C and 37% (n = 26) in grade D, with a significant increase in variance (p = 0.035). Bias did not differ between grades. After extracorporeal circulation (n = 27), percentage errors became larger, but were not different between grades. Variability during cardiothoracic surgery affected the comparison between thermodilution and non-invasive finger arterial pressure-derived cardiac output. When the main sources of variability were included, percentage errors were large. Future cardiac output methodology comparison studies should report haemodynamic variability.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available