4.5 Article

The use of capnography and the availability of airway equipment on Intensive Care Units in the UK and the Republic of Ireland

Journal

ANAESTHESIA
Volume 65, Issue 5, Pages 462-467

Publisher

WILEY
DOI: 10.1111/j.1365-2044.2010.06308.x

Keywords

-

Categories

Ask authors/readers for more resources

P>At least 20% of reported major adverse airway events occur on the intensive care unit. This study surveyed 315 (96%) of all general, satellite, hepatobiliary, cardiac and neuro-intensive care units in the UK and the Republic of Ireland, finding that only 100 (32%) units always use capnography for tracheal intubation while only 80 (25%) always use capnography for continuous monitoring of patients requiring controlled ventilation. Three hundred and ten (98%) units utilise a checklist of airway equipment, 311 (99%) check its functionality on a daily basis and 296 (94%) units have access to a bronchoscope. Whilst 297 (94%) ICUs have an airway trolley, sufficient equipment for unanticipated difficult intubation was only seen on 33 (10%) of units. Guidelines addressing minimum standards for monitoring and airway safety on ICU are not being met and remain below the standard expected.