2D LC separation and determination of bradykinin in rat muscle tissue dialysate with on-line SPE-HILIC-SPE-RP-MS

Journal

CHROMATOGRAPHIA
Volume 66, Issue 7-8, Pages 469-474

Publisher

SPRINGER HEIDELBERG
DOI: 10.1365/s10337-007-0341-4

Keywords

column liquid ch romatog ra phy; mass spectrometry; 2D Liquid chromatography; microdialysis; pepticles; bradykinin

Ask authors/readers for more resources

A 2D liquid chromatography (LC) system using hydrophilic interaction chromatography (HILIC) and reversed phase columns has been employed for comprehensive (LC x LC) separation of rat muscle tissue micro-dialysate. Incorporation of an on-line reverse-phase solid phase extraction (SPE) enrichment column in front of the first dimension enabled aqueous samples with high salt concentrations to be injected directly without compromising the chromatographic performance of the HILIC column. Since the SPE enrichment column allowed injection of large sample volumes (e.g. 450 mu 1), a capillary HILIC column (inner diameter 0.3 mm) could be employed instead of a larger column which is often used in the first dimension to load sufficient amounts of sample. The two chromatographic dimensions were connected using a column selector system with 18, 1.0 mm I.D. C-18 transition SPE columns. A PLRP C-18 column was used in the second dimension. The 2D LC system's performance was evaluated with a tryptic digest mixture of three model proteins. Good trapping accuracy (HILIC transition SPE-RP recovery >95%) and repeatability (within-and between day retention time RSDs of first and second dimension chromatography > 1 %) was achieved. A dialysis sample of rat muscle tissue was separated with the 2D system, revealing complexity and large differences in concentrations of the various compounds present, factors which could potentially interfere with the quantification and monitoring of two target analytes, arg-bradykinin and bradykinin. Subsequently, Heart-cut 2D LC-electrospray-mass spectrometry (ESI-MS) with post-column on-line standard injection was employed to monitor arg-bradykinin and bradykinin levels as a function of various muscle conditions. The method's quantification precision was RSD = 3.4% for bradykinin.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.2
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available