4.4 Article Proceedings Paper

Single photon timing resolution and detection efficiency of the IRST silicon photo-multipliers

Publisher

ELSEVIER SCIENCE BV
DOI: 10.1016/j.nima.2007.08.027

Keywords

silicon photomultiplier; opto-semiconductor; photon detection efficiency; high resolution timing; single photon

Ask authors/readers for more resources

Silicon photo-multipliers (SiPM) consist in matrices of tiny, passive quenched avalanche photo-diode cells connected in parallel via integrated resistors and operated in Geiger mode. Novel types of SiPM are being developed at FBK-IRST (trento, Italy). Despite their classical shallow junction n-on-p structure the devices are unique in their enhanced photo-detection efficiency (PDE) for short-wavelengths and in their low level of dark rate and excess noise factor. After a summary of the extensive SiPM characterization we will focus on the study of PDE and the single photon timing resolution. (C) 2007 Elsevier B.V. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available