4.8 Article

Stable-isotope dimethylation labeling combined with LC-ESI MS for quantification of amine-containing metabolites in biological samples

Journal

ANALYTICAL CHEMISTRY
Volume 79, Issue 22, Pages 8631-8638

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/ac0704356

Keywords

-

Ask authors/readers for more resources

One of the challenges associated with metabolome profiling in complex biological samples is to generate quantitative information on the metabolites of interest. In this work, a targeted metabolome analysis strategy is presented for the quantification of amine-containing metabolites. A dimethylation reaction is used to introduce a stable isotopic tag onto amine-containing metabolites followed by LC-ESI MS analysis. This labeling reaction employs a common reagent, formaldehyde, to label globally the amine groups through reductive aminadon. The performance of this strategy was investigated in the analysis of 20 amino acids and 15 amines by LC-ESI MS. It is shown that the labeling chemistry is simple, fast (< 10min reaction time), specific, and provides high yields under mild reaction conditions. The issue of isotopic effects of the labeled amines on reversed-phase (RP) and hydrophilic interaction (HILIC) LC separations was examined. It was found that deuterium labeling causes an isotope effect on the elution of labeled amines on RPLC but has no effect on HILIC LC. However, C-13-dimethyladon does not show any isotope effect on either RPLC or HIM LC, indicating that C-13-labeling is a preferred approach for relative quantification of amine-containing metabolites in different samples. The isotopically labeled 35 amine-containing analogues were found to be stable and proved to be effective in overcoming matrix effects in both relative and absolute quantification of these analytes present in a complicated sample, human urine. Finally, the characteristic mass difference provides additional structural information that reveals the existence of primary or secondary amine functional groups in aminecontaining metabolites. As an example, for a human urine sample, a total of 438 pairs of different amine-containing metabolites were detected, at signal-to-noise ratios of greater than 10, by using the labeling strategy in conjunction with RP LC-ESI Fourier-transform ion cyclotron resonance MS.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available