A Li-ion polymer pouch cell battery design for a spacesuit developed an internal short during ground storage. A detailed failure investigation found that native contamination was the most probable root cause as the failure mechanism was successfully replicated. Lessons learned are applicable to the implementation of most Li-ion cell designs for critical applications. Published by Elsevier B.V.