4.5 Article

Comparison of 99mTc-DMSA Dual-Head SPECT Versus High-Resolution Parallel-Hole Planar Imaging for the Detection of Renal Cortical Defects

Journal

AMERICAN JOURNAL OF ROENTGENOLOGY
Volume 193, Issue 2, Pages 333-337

Publisher

AMER ROENTGEN RAY SOC
DOI: 10.2214/AJR.08.1788

Keywords

Tc-99m-DMSA; acute pyelonephritis; renal cortical scanning; renal scintigraphy; SPECT

Ask authors/readers for more resources

OBJECTIVE. Renal cortical scintigraphy with Tc-99m dimer captosuccinic acid (DMSA) is the standard method to detect acute pyelonephritis and cortical scarring. Different acquisition methods have been used: planar parallel-hole or pinhole collimation and single photon emission tomography (SPECT). Publications support the superiority of each; few comparative studies have been reported, with mixed results. We have compared planar parallel-hole cortical scintigraphy and dual-head SPECT for detection of cortical defects. MATERIALS AND METHODS. Forty patients (37 children, 3 adults; 9 male, 31 female) were imaged 3 hours after injection of Tc-99m-DMSA with dual-head SPECT and planar imaging (posterior, left, and right posterior oblique views with a parallel-hole collimator). For each patient, planar and SPECT images were evaluated at different sittings, in random order, by three independent observers. Twelve cortical segments were scored as normal or reduced uptake. The linear correlation coefficient for the number of abnormal segments detected between readers, techniques, and segments was calculated. RESULTS. No significant difference was seen in the average number of abnormal segments detected by planar versus SPECT imaging; 2.1 for planar imaging and 2.2 for SPECT (p = 0.84, two-tailed). For all observers, the average correlation coefficient for SPECT alone, planar imaging alone, and between techniques (SPECT vs planar imaging) was high (r = 0.93-0.94). Applying nonparametric Spearman's rank analysis, the average correlation remained high (r = 0.70-0.75). Correlation between readers, techniques, and segments for methods and readers was also good (r = 0.69-0.77). CONCLUSION. Tc-99m-DMSA renal cortical imaging using dual-head SPECT offers no statistically significant diagnostic advantage over planar imaging for detection of cortical defects.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available