4.5 Article

Kinetic Curves of Malignant Lesions Are Not Consistent Across MRI Systems: Need for Improved Standardization of Breast Dynamic Contrast-Enhanced MRI Acquisition

Journal

AMERICAN JOURNAL OF ROENTGENOLOGY
Volume 193, Issue 3, Pages 832-839

Publisher

AMER ROENTGEN RAY SOC
DOI: 10.2214/AJR.08.2025

Keywords

breast; dynamic contrast-enhanced MRI; malignant lesions; kinetic parameters; standardization

Funding

  1. Segal Foundation
  2. DOD [W81XWH-06-1-0329]

Ask authors/readers for more resources

OBJECTIVE. The purpose of this study was to compare MRI kinetic Curve data acquired with three systems in the evaluation of malignant lesions of the breast. MATERIALS AND METHODS. The cases of 601 patients with 682 breast lesions (185 benign, 497 malignant) were selected for review. The malignant lesions were classified as ductal carcinoma in situ (DCIS). invasive ductal carcinoma (IDC), and other. The dynamic MRI protocol consisted of one unenhanced and three to seven contrast-enhanced images acquired with one of three imaging protocols and systems. An experienced radiologist analyzed the shapes of the kinetic curves according to the BI-RADS lexicon. Several quantitative kinetic parameters were calculated. and the kinetic parameters of malignant lesions were compared across the three systems. RESULTS. Imaging protocol and system 1 were used to image 304 malignant lesions (185 IDC, 62 DCIS); imaging protocol and system 2, 107 lesions (72 IDC, 21 DCIS); and imaging protocol and system 3, 86 lesions (64 IDC, 17 DCIS). Compared with those visualized with imaging protocols and systems 1 and 2. IDC lesions visualized with imaging protocol and system 3 had significantly less initial enhancement longer time to peak enhancement, and a slower washout rate (p < 0.004). Only 47% of IDC lesions imaged with imaging protocol and system 3 exhibited washout type Curves, compared with 75% and 74% of those imaged with imaging protocols and systems 2 and 1, respectively. The diagnostic accuracy of kinetic analysis was lowest for imaging protocol and system 3. but the difference was not statistically significant. CONCLUSION. The kinetic curve data on malignant lesions acquired with one system showed significantly lower initial contrast uptake and a different Curve shape in comparison with data acquired with the other two systems. Differences in k-space sampling, T1 weighting, and magnetization transfer effects may be explanations for the difference.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available