INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Volume 87, Issue -, Pages 636-652Publisher
PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2015.03.081
Keywords
Minichannel; Flow patterns; Heat transfer coefficient; Nucleate boiling; Convective boiling
Categories
Funding
- French Environment and Energy Management Agency, ADEME (Agence de l'Environnement et de la Maitrise de l'Energie), TIGRE project [2011-0056]
Ask authors/readers for more resources
This paper presents new experimental data concerning flow boiling heat transfer in minichannel at high saturation temperatures. The experimental data were obtained in a horizontal 3.00 mm inner diameter stainless steel tube with R-245fa as working fluid. The mass velocity ranges from 100 to 1500 kg/m(2) s, the heat flux varies from 10 to 50 kW/m(2) and the inlet vapor quality from 0 to 1. This experimental work is characterized by a saturation temperature ranging from 100 degrees C to 120 degrees C. Flow boiling heat transfer coefficients in these conditions have not been reported in the open literature so far. Four flow patterns are likely to appear in these conditions: intermittent flow, annular flow, dryout flow and mist flow regimes. The kind of flow pattern has a major influence on the heat transfer mechanisms. The influence of the mass velocity and the heat flux was investigated to identify the dominant heat transfer mechanisms. At high saturation temperatures, the experimental results clearly show the dominance of nucleate boiling over a wide range of vapor quality. (C) 2015 Elsevier Ltd. All rights reserved.
Authors
I am an author on this paper
Click your name to claim this paper and add it to your profile.
Reviews
Recommended
No Data Available