4.5 Article

Clinical Application of Readout-Segmented-Echo-Planar Imaging for Diffusion-Weighted Imaging in Pediatric Brain

Journal

AMERICAN JOURNAL OF NEURORADIOLOGY
Volume 32, Issue 7, Pages 1274-1279

Publisher

AMER SOC NEURORADIOLOGY
DOI: 10.3174/ajnr.A2481

Keywords

-

Funding

  1. National Institutes of Health [1R01 EBC08706, 1R01 EB008706S1, 5R01 EB002711, 1R01 EB006526, 1R21 EB006860]
  2. Center of Advanced MR Technology at Stanford [P41RR09784]
  3. Lucas Foundation
  4. Oak Foundation
  5. Swedish Research Council [K2007-53P-20322-01-4]

Ask authors/readers for more resources

BACKGROUND AND PURPOSE: RS-EPI has been suggested as an alternative approach to EPI for high-resolution DWI with reduced distortions. To determine whether RS-EPI is a useful approach for routine clinical use, we implemented GRAPPA-accelerated RS-EPI DWI at our pediatric hospital and graded the images alongside standard accelerated (ASSET) EPI DWI used routinely for clinical studies. MATERIALS AND METHODS: GRAPPA-accelerated RS-EPI DWIs and ASSET EPI DWIs were acquired on 35 ped atric patients using a 3T system in 35 pediatric patients. The images were graded alongside each other by using a 7-point Likert scale as follows: 1, nondiagnostic; 2, poor; 3, acceptable; 4, standard; 5, above average; 6, good: and 7, outstanding. RESULTS: The following were the average scores for EPI and RS-EPI, respectively: resolution, 3.5/5.2; distortion level, 2.9/6.0: SNR, 3.4/4.1; lesion conspicuity, 3.3/5.9; and diagnostic confidence, 3.2/6.0. Overall, the RS-EPI had significantly improved diagnostic confidence and more reliably defined the extent and structure of several lesions. Although ASSET EPI scans had better SNR per scanning time, the higher spatial resolution as we:I as reduced blurring and distortions on RS-EPI scans helped to better reveal important anatomic details at the cortical-subcortica levels, brain stem, temporal and inferior frontal lopes, skull base, sinonasal cavity, cranial nerves, and orbits. CONCLUSIONS: This work shows the importance of both resolution and decreased distortions in the clinics, which can be accomplished by a combination of parallel imaging and alternative k-space trajectories such as RS-EPI.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available