Impact of a program to prevent central line-associated bloodstream infection in the zero tolerance era

Journal

AMERICAN JOURNAL OF INFECTION CONTROL
Volume 38, Issue 6, Pages 434-439

Publisher

MOSBY-ELSEVIER
DOI: 10.1016/j.ajic.2009.11.012

Keywords

Bloodstream infection; prevention; intensive care unit; step-down unit; zero tolerance; central venous catheter; epidemiology; central line bundle

Ask authors/readers for more resources

Background: Central line-associated bloodstream infection (CLABSI) is one of the most important health care-associated infections in the critical care setting. Methods: A quasiexperimental study involving multiple interventions to reduce the incidence of CLABSI was conducted in a medical-surgical intensive care unit (ICU) and in 2 step-down units (SDUs). From March 2005 to March 2007 (phase 1 [P1]), some Centers for Disease Control and Prevention evidence-based practices were implemented. From April 2007 to April 2009 (P2), we intervened in these processes at the same time that performance monitoring was occurring at the bedside, and we implemented the Institute for Healthcare Improvement central line bundle for all ICU and SDU patients requiring central venous lines. Results: The mean incidence density of CLABSI per 1000 catheter-days in the ICU was 6.4 in phase 1 and 3.2 in phase 2, P < .001. The mean incidence density of CLABSI per 1000 catheter-days in the SDUs was 4.1 in phase 1 and 1.6 in phase 2, P = 5.005. Conclusion: These results suggest that reducing CLABSI rates in an ICU setting is a complex process that involves multiple performance measures and interventions that can also be applied to SDU settings.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available