4.6 Article

Evaluation of Optical Coherence Tomography Retinal Thickness Parameters for Use in Clinical Trials for Neovascular Age-Related Macular Degeneration

Journal

INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE
Volume 50, Issue 7, Pages 3378-3385

Publisher

ASSOC RESEARCH VISION OPHTHALMOLOGY INC
DOI: 10.1167/iovs.08-2728

Keywords

-

Categories

Funding

  1. NIH [EY03040]
  2. NEI [R01 EY014375]

Ask authors/readers for more resources

PURPOSE. To investigate the relationship between automated and manually derived measurements of central retinal thickness from optical coherence tomography (OCT) and to determine the relationship between the foveal center point (FCP) and the foveal central subfield (FCS) in neovascular age-related macular degeneration (AMD). METHODS. Data were collected from 216 patients with newly diagnosed neovascular AMD, who underwent StratusOCT imaging at diagnosis. Raw StratusOCT images for each patient were analyzed with the publicly available custom software OCTOR, which allows accurate manual grading of OCT B-scans. Manually derived central retinal thickness measurements were compared with measurements obtained from automated StratusOCT analysis. Manually obtained measurements of FCP and FCS were also compared. RESULTS. The mean (+/- SD) difference in thickness between automated and manually derived FCP thickness was 7.9 mu m (+/- 90.8), but the maximum difference was 455 mu m. The limits of agreement (95% confidence interval), between automated and manually obtained FCP thicknesses, were -173.7 mu m (lower limit) and 189.6 mu m (upper limit), with a coefficient of determination (R-2) of 0.49 (P < 0.001). In contrast, the R-2 for manually derived FCP and manually derived FCS thickness was 0.94 (P < 0.001), with a smaller mean (+/- SD) difference in thickness of 13.8 mu m (+/- 29.8). CONCLUSIONS. Manual correction of errors in automated OCT segmentation may be necessary for accurate interpretation of anatomic outcomes for clinical trials of neovascular AMD. In addition, although measurement of FCS remains preferable for assessment of central retinal thickness, accurate measurement of FCP may represent an adequate alternative when FCS is unavailable. (Invest Ophthalmol Vis Sci. 2009;50:3378-3385) DOI:10.1167/iovs.08-2728

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.6
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available