4.5 Article

Calibration-free wavelength-modulation spectroscopy for measurements of gas temperature and concentration in harsh environments

Journal

APPLIED OPTICS
Volume 48, Issue 29, Pages 5546-5560

Publisher

OPTICAL SOC AMER
DOI: 10.1364/AO.48.005546

Keywords

-

Categories

Funding

  1. Air Force Office of Scientific Research (AFOSR)
  2. Aerospace and Materials Directorate

Ask authors/readers for more resources

We present a practical implementation of calibration-free wavelength-modulation spectroscopy with second harmonic detection (WMS-2f) for measurements of gas temperature and concentration in harsh environments. The method is applicable to measurements using lasers with synchronous wavelength and intensity modulation (such as injection current-tuned diode lasers). The key factors that enable measurements without the on-site calibration normally associated with WMS are (1) normalization of the WMS-2f signal by the first harmonic (1f) signal to account for laser intensity, and (2) the inclusion of laser-specific tuning characteristics in the spectral-absorption model that is used to compare with measured 1f-normalized, WMS-2f signals to infer gas properties. The uncertainties associated with the calibration-free WMS method are discussed, with particular emphasis on the influence of pressure and optical depth on the WMS signals. Many of these uncertainties are also applicable to calibrated WMS measurements. An example experimental setup that combines six tunable diode laser sources between 1.3 and 2.0 mu m into one probe beam for measurements of temperature, H2O, and CO2 is shown. A hybrid combination of wavelength and frequency demultiplexing is used to distinguish among the laser signals, and the optimal set of laser-modulation waveforms is presented. The system is demonstrated in the harsh environment of a ground-test scramjet combustor. A comparison of direct absorption and 1f-normalized, WMS-2f shows a factor of 4 increase in signal-to-noise ratio with the WMS technique for measurements of CO2 in the supersonic flow. Multidimensional computational fluid-dynamics (CFD) calculations are compared with measurements of temperature and H2O using a simple method that accounts for the influence of line-of-sight (LOS) nonuniformity on the absorption measurements. The comparisons show the ability of the LOS calibration-free technique to gain useful information about multidimensional CFD models. (C) 2009 Optical Society of America

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available