4.4 Article Proceedings Paper

The use of FDG-PET/CT and diffusion-weighted magnetic resonance imaging for response prediction before, during and after preoperative chemoradiotherapy for rectal cancer

Journal

ACTA ONCOLOGICA
Volume 49, Issue 7, Pages 956-963

Publisher

INFORMA HEALTHCARE
DOI: 10.3109/0284186X.2010.498439

Keywords

-

Categories

Ask authors/readers for more resources

Purpose. To investigate the use of FDG-PET/CT before, during and after chemoradiotherapy (CRT) and diffusion-weighted magnetic resonance imaging (DW-MRI) before CRT for the prediction of pathological response (pCR) in rectal cancer patients. Material and methods. Twenty-two rectal cancer patients treated with long course CRT were included. An FDG-PET/CT was performed prior to the start of CRT, after 10 to 12 fractions of CRT and five weeks after the end of CRT. The tumor was delineated using a gradient based delineation method and the maximal standardized uptake values (SUV(max)) were calculated. A DW-MRI was performed before start of CRT. Mean apparent diffusion coefficients (ADC) were determined. The Delta SUV(max) during and after CRT and the initial ADC values were correlated to the histopathological findings after total mesorectal excision (TME). Results. Delta SUV(max) during and after CRT significantly correlated with the pathological response to treatment (during CRT: Delta SUV(max) = 59% +/- 12% for pCR vs. 25% +/- 27% if no pCR, p = 0.0036; post-CRT: 90% +/- 11 for pCR vs. 63% +/- 22 if no pCR p = 0.013). ROC curve analysis revealed an optimal threshold for Delta SUV(max) of 40% during CRT and 76% after CRT. The initial ADC value was also significantly correlated with pCR (0.94 +/- 0.12 x 10(-3) mm(2)/s for pCR vs. 1.2 +/- 0.24 x 10(-3) mm(2)/s, p=0.002) and ROC curve analysis revealed an optimal threshold of 1.06 x 10(-3) mm(2)/s. Combining the provided Delta SUV(max) thresholds during and after CRT increased specificity of the prediction (sensitivity 100% and specificity 94%). The combination of the thresholds for the initial ADC value and the Delta SUV(max) during CRT increased specificity of the prediction to a similar level (sensitivity of 100% and specificity of 94%). Conclusions. The combination of the different time points and the different imaging modalities increased the specificity of the response assessment both during and after CRT.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.4
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available