4.5 Article

Acceptability and accuracy of a non-endoscopic screening test for Barrett's oesophagus in primary care: cohort study

Journal

BMJ-BRITISH MEDICAL JOURNAL
Volume 341, Issue -, Pages -

Publisher

BMJ PUBLISHING GROUP
DOI: 10.1136/bmj.c4372

Keywords

-

Funding

  1. Medical Research Council
  2. NIHR School for Primary Care Research
  3. BD Diagnostics
  4. Cambridge Experimental Cancer Medicine Centre
  5. National Institute for Health Research Cambridge Biomedical Research Centre
  6. Cancer Research UK [11021] Funding Source: researchfish
  7. Cancer Research UK
  8. The Francis Crick Institute [10119] Funding Source: researchfish
  9. Medical Research Council [G0601390, MC_U105365007] Funding Source: researchfish
  10. MRC [G0601390, MC_U105365007] Funding Source: UKRI

Ask authors/readers for more resources

Objectives To determine the accuracy and acceptability to patients of non-endoscopic screening for Barrett's oesophagus, using an ingestible oesophageal sampling device (Cytosponge) coupled with immunocytochemisty for trefoil factor 3. Design Prospective cohort study. Setting 12 UK general practices, with gastroscopies carried out in one hospital endoscopy unit. Participants 504 of 2696 eligible patients (18.7%) aged 50 to 70 years with a previous prescription for an acid suppressant (H2 receptor antagonist or proton pump inhibitor) for more than three months in the past five years. Main outcome measures Sensitivity and specificity estimates for detecting Barrett's oesophagus compared with gastroscopy as the ideal method, and patient anxiety (short form Spielberger state trait anxiety inventory, impact of events scale) and acceptability (visual analogue scale) of the test. Results 501 of 504 (99%) participants (median age 62, male to female ratio 1:1.2) successfully swallowed the Cytosponge. No serious adverse events occurred. In total, 3.0% (15/501) had an endoscopic diagnosis of Barrett's oesophagus (>= 1 cm circumferential length, median circumferential and maximal length of 2 cm and 5 cm, respectively) with intestinal metaplasia. Compared with gastroscopy the sensitivity and specificity of the test was 73.3% (95% confidence interval 44.9% to 92.2%) and 93.8% (91.3% to 95.8%) for 1 cm or more circumferential length and 90.0% (55.5% to 99.7%) and 93.5% (90.9% to 95.5%) for clinically relevant segments of 2 cm or more. Most participants (355/496, 82%, 95% confidence interval 78.9% to 85.1%) reported low levels of anxiety before the test, and scores remained within normal limits at follow-up. Less than 4.5% (2.8% to 6.1%) of participants reported psychological distress a week after the procedure. Conclusions The performance of the Cytosponge test was promising and the procedure was well tolerated. These data bring screening for Barrett's oesophagus into the realm of possibility. Further evaluation is recommended.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.5
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available