4.8 Article

Conducting polymers on hydrogel-coated neural electrode provide sensitive neural recordings in auditory cortex

Journal

ACTA BIOMATERIALIA
Volume 6, Issue 1, Pages 57-62

Publisher

ELSEVIER SCI LTD
DOI: 10.1016/j.actbio.2009.07.034

Keywords

Signal-to-noise ratio; Hydrogel; Conducting polymer; Neural electrode; Neural signal recording

Funding

  1. National Institutes of Health [NINDS-N01-NS-1-2338]
  2. National Science Foundation [DMR-0084304, DMR-0518079]
  3. Army Research Office [W911NF-06-1-0218]
  4. Academic Research Funding Tier 1 [RG65/08]
  5. National Medical Research Council [NMRC/NIG/00602009]
  6. NATIONAL INSTITUTE OF BIOMEDICAL IMAGING AND BIOENGINEERING [P41EB002030] Funding Source: NIH RePORTER

Ask authors/readers for more resources

Recently, a significant amount of effort has been dedicated to understanding factors that influence the functionality of bio-electronic sensors and to development of novel coating technologies for modifying biosensor surfaces. Due to its well-known biocompatibility, alginate hydrogel (HG) has been used as a coating material on neural electrodes for promoting intimate cellular integration, providing a scaffold for local drug delivery, and creating a mechanical buffer between hard electrodes and the soft tissues of the central nervous system. However, neural signal recordings using HG-coated electrodes in animal models are still poorly evaluated. Here, we investigated the effect of the proximity of source neurons around the electrode sites using HG coatings with various thicknesses deposited on microfabricated electrodes, implanted in auditory cortex of guinea pigs. We also evaluated the role of the conducting polymer poly(3,4-ethylenedioxythiophene) (PEDOT) in improving the recording functionality of the HG-coated neural electrodes. A significant loss in recording functionality was observed with thicker HG coatings, as determined by the number of clearly detectable units (30% with 80 mu m thick coatings) and average signal-to-noise ratios (3.91 with 80 mu m thick coatings). However, deposition of the conducting polymer PEDOT on the electrode sites restored the lost functionality of the electrodes caused by the HG coatings (30 mu m). These conducting polymer/HG coatings have the potential to improve long-term performance of the neural electrodes not only by improving the electrode biocompatibility but also by facilitating more efficient signal transmission. (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available