4.8 Article

Mapping the Pharyngeal and Intestinal pH of Caenorhabditis elegans and Real-Time Luminal pH Oscillations Using Extended Dynamic Range pH-Sensitive Nanosensors

Journal

ACS NANO
Volume 7, Issue 6, Pages 5577-5587

Publisher

AMER CHEMICAL SOC
DOI: 10.1021/nn401856u

Keywords

C. elegans; lumen; fluorescence; pH measurement; nanosensors; real-time; pH oscillations

Funding

  1. Biotechnology and Biosciences Research Council (BBSRC) CASE studentship [BG0176381]

Ask authors/readers for more resources

Extended dynamic range pH-sensitive ratiometric nanosensors, capable of accurately mapping the full physiological pH range, have been developed and used to characterize the pH of the pharyngeal and intestinal lumen of Caenorhabditis elegans in real-time. Nanosensors, 40 nm in diameter, were prepared by conjugating pH-sensitive fluorophores, carboxyfluorescein (FAM) and Oregon Green (OG) in a 1:1 ratio, and a reference fluorophore, 5-(and-6)-carboxytetramethylrhodamine (TAMRA) to an inert polyacrylamide matrix. Accurate ratiometric pH measurements were calculated through determination of the fluorescence ratio between the pH-sensitive and reference fluorophores. Nanosensors were calibrated with an automated Image analysis system and validated to demonstrate a pH measurement resolution of +/- 0.17 pH units. The motility of C. elegans populations, as an indicator for viability, showed nematodes treated with nanosensors, for concentrations ranging from 50.00 to 3.13 mg/mL, were not statistically different to nematodes not challenged with nanosensors up to a period of 4 days (p <0.05). The nanosensors were also found to remain in the C. elegans lumen >24 h after nanosensor challenge was removed. The pH of viable C. elegans lumen was found to range from 5.96 +/- 031 in the anterior pharynx to 339 +/- 0.09 in the posterior intestine. The pharyngeal pumping rate, which dictates the transfer of ingested material from the pharynx to the intestine, was found to be temperature dependent. Imaging C. elegans at 4 degrees C reduced the pharyngeal pumping rate to 7 contractions/min and enabled the reconstruction of rhythmic pH oscillations in the intestinal lumen in real-time with fluorescence microscopy.

Authors

I am an author on this paper
Click your name to claim this paper and add it to your profile.

Reviews

Primary Rating

4.8
Not enough ratings

Secondary Ratings

Novelty
-
Significance
-
Scientific rigor
-
Rate this paper

Recommended

No Data Available
No Data Available